The DOI matches its Crossref record.
Optical recordings in the rabbit heart show that defibrillation strength shocks prolong the duration of depolarization and the refractory period.
Abstract
The present data were obtained using the technique of optical recording with the voltage-sensitive dye WW781. This technique, unlike electrical methods, was able to provide uninterrupted recordings free of artifacts during defibrillation shocks. Optical recordings were made from sites on the ventricular epicardium of perfused rabbit hearts during electrical pacing. Continuous recordings of the electrophysiological responses of an intact heart to defibrillation threshold-strength shocks were made. It was shown that these shocks were able to stimulate normal-appearing action potentials in nonrefractory myocardium. A new and unexpected finding was that defibrillation threshold-strength shocks were also able to evoke a sustained, depolarizing response from myocardium already undergoing an action potential. This prolonged the time that the myocardium remained in the depolarized state. Prolongation of the depolarized state was accompanied by an equal prolongation of the refractory period. There was no indication that this depolarizing shock response was due to damage of the myocardium by the shock, to heterogeneous electrical responses in the optical recording area, or to the methods used in this study. It is hypothesized that these shocks were able to elicit a new action potential in already depolarized myocardium by hyperpolarizing portions of the myocardium's cellular membranes and, in so doing, to reactivate the fast sodium current. This effect, if prevalent in a fibrillating ventricle, could play a role in the defribillation process by effectively resynchronizing electrical activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Efimov, I. R., Nikolski, V. P., & Salama, G. (2004) · Circulation Research · doi:10.1161/01.res.0000130529.18016.35 · Cited by 390
Ventricular Fibrillation: Mechanisms of Initiation and Maintenance
Jalife, J. (2000) · Annual Review of Physiology · doi:10.1146/annurev.physiol.62.1.25 · Cited by 378
Virtual Electrode–Induced Phase Singularity: A Basic Mechanism of Defibrillation Failure
Efimov, I. R., Cheng, Y., Van Wagoner, D. R., Mazgalev, T., & Tchou, P. J. (1998) · Circulation Research · doi:10.1161/01.res.82.8.918 · Cited by 290
Optical Imaging of Voltage and Calcium in Cardiac Cells & Tissues
Herron, T. J., Lee, P., & Jalife, J. (2012) · Circulation Research · doi:10.1161/circresaha.111.247494 · Cited by 289
Suddath, W. O., Deychak, Y., & Varghese, P. J. (2001) · Annals of Emergency Medicine · doi:10.1067/mem.2001.115540 · Cited by 18
Metadata
- Authors
- Dillon, S. M.
- Venue
- Circulation Research
- Published
- 1991-09
- Volume
- 69
- Issue
- 3
- Pages
- 842-856
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2099252075
- Cited by
- 174
- References
- 0
- FWCI
- 7.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical recordings in the rabbit heart show that defibrillation strength shocks prolong the duration of depolarization and the refractory period. https://app.cochat.ai/papers/10.1161/01.res.69.3.842
- The paper
- Dillon, S. M. (1991). Optical recordings in the rabbit heart show that defibrillation strength shocks prolong the duration of depolarization and the refractory period. Circulation Research. https://doi.org/10.1161/01.res.69.3.842
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.