Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 216

The DOI matches its Crossref record.

Mechanism of augmented rate of left ventricular filling during exercise.

Open access
Cheng, C P, Igarashi, Y, Little, W C · 1992 · Circulation Research

Abstract

At rest, most of left ventricular (LV) filling occurs early in diastole. This LV filling occurs in response to the pressure gradient produced as LV pressure falls below left atrial (LA) pressure. Because mitral valve flow occurs in response to an LA to LV pressure gradient, augmented diastolic mitral valve flow during exercise may be due to an increased mitral valve pressure gradient resulting from a rise in LA pressure and/or a fall in LV early diastolic pressure. Accordingly, we studied 13 conscious dogs, instrumented to measure micromanometer LV and LA pressures, and determined LV volume from three ultrasonic dimensions during exercise. The animals ran on a treadmill for 8-15 minutes at 5-8 miles/hr. With reflexes intact, during exercise, the heart rate increased from 116 +/- 20 to 189 +/- 24 beats per minute (mean +/- SD, p less than 0.01), the maximum rate of change of LV volume (dV/dtmax) increased from 185 +/- 44 to 282 +/- 76 ml/sec (p less than 0.01), the ejection fraction and cardiac output increased, and the duration of diastole decreased from 296 +/- 83 to 162 +/- 71 msec (p less than 0.01). Mitral valve opening pressure, mean LA pressure (10.9 +/- 4.4 versus 10.2 +/- 3.9 mm Hg, p = NS), and LV end-diastolic pressure (12.8 +/- 4.8 versus 13.1 +/- 3.3 mm Hg, p = NS) were all relatively unchanged. The time constant of the fall of isovolumic LV pressure decreased from 28 +/- 3.3 to 21 +/- 4.4 msec (p less than 0.05). The early diastolic portion of the LV pressure-volume loop was shifted downward during exercise, with the minimum LV pressure decreasing from 3.3 +/- 2.8 to -2.8 +/- 3.4 mm Hg (p less than 0.05) and the maximum mitral valve pressure gradient increasing from 5.5 +/- 1.7 to 11.8 +/- 3.5 mm Hg (p less than 0.01). A similar downward shift of the early diastolic portion of the LV pressure-volume loop was produced by infusion of dobutamine (6 micrograms/kg/min i.v.) at rest, as well as by exercise when the heart rate was held constant by right ventricular pacing at 190-210 beats per minute. The downward shift during exercise was prevented by beta-blockade (metoprolol, 0.5 mg/kg i.v.). We conclude that during exercise, sympathetic stimulation and tachycardia produce a downward shift of the early diastolic portion of the LV pressure-volume loop.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.70.1.9

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 216

Metadata

Authors
Cheng, C. P., Igarashi, Y., & Little, W. C.
Venue
Circulation Research
Published
1992-01
Volume
70
Issue
1
Pages
9-19
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2084350797
Cited by
216
References
0
FWCI
4.07
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mechanism of augmented rate of left ventricular filling during exercise. https://app.cochat.ai/papers/10.1161/01.res.70.1.9
The paper
Cheng, C. P., Igarashi, Y., & Little, W. C. (1992). Mechanism of augmented rate of left ventricular filling during exercise. Circulation Research. https://doi.org/10.1161/01.res.70.1.9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.