Epicardial mapping of ventricular defibrillation with monophasic and biphasic shocks in dogs.
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
To study the mechanism of defibrillation and the reason for the increased defibrillation efficacy of biphasic waveforms, the potential gradient in a 32 x 30-mm region of the right ventricle in 15 dogs was progressively lowered in four steps while a strong potential gradient field was maintained throughout the rest of the ventricular myocardium. The volume of right ventricle beneath the plaque was 10 +/- 2% of the total ventricular mass. A 10-msec monophasic (eight dogs) or 5/5-msec biphasic (seven dogs) truncated exponential shock 30% above the defibrillation threshold voltage was given via electrodes on the left ventricular apex and right atrium to create the strong potential gradient field. Simultaneously, a weaker shock with the same waveform but opposite polarity was given via mesh electrodes on either side of the small right ventricular region to cancel part of the potential difference in the region and to create one of the four levels of potential gradient fields. Shock potentials and activations were recorded from 117 epicardial electrodes in the small region, and in one dog global epicardial activations and potentials were recorded from a sock containing 72 electrodes. Each gradient field was tested 10 times for successful defibrillation after 10 seconds of electrically induced fibrillation. For both monophasic and biphasic shocks, the percentage of successful defibrillation attempts decreased (p < 0.05) as the potential gradient decreased in the small region. Defibrillation was successful approximately 80% of the time for a mean +/- SD potential gradient of 5.4 +/- 0.8 V/cm for monophasic shocks and 2.7 +/- 0.3 V/cm for biphasic shocks (p < 0.05). No postshock activation fronts arose from the small region for eight waveform when the gradient was more than 5 V/cm. For both waveforms, the postshock activation fronts after the shocks were markedly different from those just before the shock and exhibited either a focal origin or unidirectional conduction.(ABSTRACT TRUNCATED AT 400 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Allessie, M. A., Bonke, F. I., & Schopman, F. J. (1977) · Circulation Research · doi:10.1161/01.res.41.1.9 · Cited by 1,066
Termination of ventricular fibrillation in dogs by depolarizing a critical amount of myocardium
Zipes, D. P., Fischer, J., King, R. M., deB. Nicoll, A., & Jolly, W. W. (1975) · The American Journal of Cardiology · doi:10.1016/0002-9149(75)90865-6 · Cited by 487
Chen, P. S., Shibata, N., Dixon, E. G., Wolf, P. D., Danieley, N. D., Sweeney, M. B., Smith, W. M., & Ideker, R. E. (1986) · Journal of Clinical Investigation · doi:10.1172/jci112378 · Cited by 236
Self-citationElectrophysiological Effects of Monophasic and Biphasic Stimuli in Normal and Infarcted Dogs
Wharton, J. M., Richard, V. J., Murry, C. E., Dixon, E. G., Reimer, K. A., MEADOR, J., Smith, W., & Ideker, R. E. (1990) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1990.tb02174.x · Cited by 53
Self-citationA New Sock Electrode for Recording Epicardial Activation from the Human Heart: One Size Fits All
WORLEY, S. J., Ideker, R. E., Mastrototaro, J. J., Smith, W., Vidaillet, H. J., Jr., Chen, P., & Lowe, J. E. (1987) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1987.tb05921.x · Cited by 36
Self-citation
Cited by
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
SIMS, J. J., MILLER, A. W., & UJHELYI, M. R. (2000) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2000.tb00025.x · Cited by 27
Metadata
- Authors
- Zhou, X., Daubert, J. P., Wolf, P. D., Smith, W. M., & Ideker, R. E.
- Venue
- Circulation Research
- Published
- 1993-01
- Volume
- 72
- Issue
- 1
- Pages
- 145-160
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2019503208
- Cited by
- 164
- References
- 5
- FWCI
- 11.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.