CoChat

Microscopic conduction in cultured strands of neonatal rat heart cells measured with voltage-sensitive dyes.

Open access
Fast, V G, Kléber, A G · 1993 · Circulation Research
Cited by 157

The DOI matches its Crossref record.

Abstract

Microscopic discontinuities in electrical activation were assessed in synthetic strands of neonatal rat myocytes cultured on a growth-directing matrix. An optical method using voltage-sensitive dye (RH-237) and a photodiode technique was used for recordings of membrane potential changes with subcellular resolution. Spatial resolution of the method (diameter of measurement area, 5.5 microns; interdiode distance, 30 microns) allowed for simultaneous measurements of cytoplasmic conduction time within a single cell and junctional conduction time across the cell border. In one-dimensional cell chains, where cells were juxtaposed by end-to-end connections but devoid of lateral connections, propagation of the excitation wave was strongly nonuniform: cytoplasmic conduction time was 38 +/- 30 (mean +/- SD) microseconds (n = 37), whereas junctional conduction time was 118 +/- 40 microseconds (n = 27, P < .0001). A mean delay introduced by a single junction was 80 microseconds, or 51% of conduction time. In two-dimensional strands consisting of several cells in width, which exhibited lateral as well as end-to-end connections, inhomogeneity of conduction was smaller: the cytoplasmic and junctional conduction times were 57 +/- 30 (n = 46) and 89 +/- 40 (n = 48) microseconds, respectively (P < .0001); mean junctional conduction delay was 32 microseconds (22% of conduction time). Mathematical modeling suggested that the averaging effect of lateral connections is caused by lateral convergence of local excitatory current beyond and lateral divergence before end-to-end connections. Our results demonstrate that the current flow through lateral cell-to-cell connections smooth the excitation wave front during longitudinal conduction in myocardial tissue.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.73.5.914

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 157

Metadata

Authors
Fast, V. G., & Kléber, A. G.
Venue
Circulation Research
Published
1993-11
Volume
73
Issue
5
Pages
914-925
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2108925739
Cited by
157
References
0
FWCI
6.53
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microscopic conduction in cultured strands of neonatal rat heart cells measured with voltage-sensitive dyes. https://app.cochat.ai/papers/10.1161/01.res.73.5.914
The paper
Fast, V. G., & Kléber, A. G. (1993). Microscopic conduction in cultured strands of neonatal rat heart cells measured with voltage-sensitive dyes. Circulation Research. https://doi.org/10.1161/01.res.73.5.914

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.