Anisotropic conduction in monolayers of neonatal rat heart cells cultured on collagen substrate.
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Anisotropic impulse conduction was studied in neonatal rat heart cell monolayers produced by culturing cells on a growth-directing substrate of collagen. Monolayers consisting of parallel-oriented cells without visible intercellular clefts were selected for experiments; cell lengths and widths were 65.8 +/- 12.5 and 12.2 +/- 3.2 microns (n = 49), respectively. Action potential upstrokes were measured by using 12 photodiodes selected within a 10x10 diode array and a voltage-sensitive dye (RH-237). The size of the area sensed by a single diode was 14 x 14 microns. High-density multiple recordings (resolution, up to 15 microns) demonstrated the variability of local activation delays and of the maximal rate of rise of the action potential upstroke (Vmax), which are presumably related to the microscopic cellular architecture. Mean macroscopic conduction velocities measured over distances of 135 microns were 34.6 +/- 4.5 and 19.0 +/- 4.3 cm/s (mean +/- SD, n = 13, P < .0001) in longitudinal and transverse directions, respectively. The anisotropic velocity ratio was 1.89 +/- 0.38 (n = 13). Mean Vmax was not significantly different in two directions (122.0 +/- 17.4 V/s longitudinally versus 125.2 +/- 15.6 V/s transversely, n = 13, P = NS). In conclusion, we developed an anisotropic cell culture model suitable for studying impulse conduction with cellular resolution. The anisotropic velocity ratio was close to values measured in vivo. By contrast, Vmax was not dependent on the direction of propagation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Initiating Reentry: The Role of Nonuniform Anisotropy in Small Circuits
SPACH, M. S., & JOSEPHSON, M. E. (1994) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1994.tb01157.x · Cited by 266
Cited by
Basic Mechanisms of Cardiac Impulse Propagation and Associated Arrhythmias
KLÉBER, A. G., & RUDY, Y. (2004) · Physiological Reviews · doi:10.1152/physrev.00025.2003 · Cited by 1,083
“Neonatal tissue in culture or in vivo (94, 120) and remodeled tissue in areas surrounding myocardial infarction (251, 256, 311) show a more regularly distributed and spaced localization of gap junctions of about equal size around the cell perimeter.”
BackgroundResultInfluentialSelf-citationShaw, R. M., & Rudy, Y. (1997) · Circulation Research · doi:10.1161/01.res.81.5.727 · Cited by 670
Electrospun fine-textured scaffolds for heart tissue constructs
Zong, X., Bien, H., Chung, C.-Y., Yin, L., Fang, D., Hsiao, B. S., Chu, B., & Entcheva, E. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.01.052 · Cited by 641
Rohr, S., Kucera, J. P., & Kléber, A. G. (1998) · Circulation Research · doi:10.1161/01.res.83.8.781 · Cited by 271
Bursac, N., Parker, K. K., Iravanian, S., & Tung, L. (2002) · Circulation Research · doi:10.1161/01.res.0000047530.88338.eb · Cited by 268
Metadata
- Authors
- Fast, V. G., & Kléber, A. G.
- Venue
- Circulation Research
- Published
- 1994-09
- Volume
- 75
- Issue
- 3
- Pages
- 591-595
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2102960647
- Cited by
- 95
- References
- 1
- FWCI
- 3.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Anisotropic conduction in monolayers of neonatal rat heart cells cultured on collagen substrate. https://app.cochat.ai/papers/10.1161/01.res.75.3.591
- The paper
- Fast, V. G., & Kléber, A. G. (1994). Anisotropic conduction in monolayers of neonatal rat heart cells cultured on collagen substrate. Circulation Research. https://doi.org/10.1161/01.res.75.3.591
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.