Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 168

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Osmotic Compression of Single Cardiac Myocytes Eliminates the Reduction in Ca 2+ Sensitivity of Tension at Short Sarcomere Length

McDonald, Kerry S., Moss, Richard L.·1995·Circulation Research

Abstract

Abstract According to the Frank-Starling relation, cardiac output varies as a function of end-diastolic volume of the ventricle. The cellular basis of the relation is thought to involve length-dependent variations in Ca 2+ sensitivity of tension; ie, as sarcomere length is increased in cardiac muscle, Ca 2+ sensitivity of tension also increases. One possible explanation for this effect is that the decrease in myocyte diameter as muscle length is increased reduces the lateral spacing between thick and thin filaments, thereby increasing the likelihood of cross-bridge interaction with actin. To examine this idea, we measured the effects of osmotic compression of single skinned cardiac myocytes on Ca 2+ sensitivity of tension. Single myocytes from rat enzymatically digested ventricles were attached to a force transducer and piezoelectric translator, and tension-pCa relations were subsequently characterized at short sarcomere length (SL), at the same short SL in the presence of 2.5% dextran, and at long SL. The pCa (−log[Ca 2+ ]) for half-maximal tension (ie, pCa 50 ) increased from 5.54±0.09 to 5.65±0.10 (n=7, mean±SD, P <.001) as SL was increased from ≈1.85 to ≈2.25 μm. Osmotic compression of myocytes at short length also increased Ca 2+ sensitivity of tension, shifting tension-pCa relations to [Ca 2+ ] levels similar to those observed at long length (pCa 50 , 5.68±0.11). These results support the idea that the length dependence of Ca 2+ sensitivity of tension in cardiac muscle arises in large part from the changes in interfilament lattice spacing that accompany changes in SL.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.77.1.199

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 168

Metadata

Authors
McDonald, K. S., & Moss, R. L.
Venue
Circulation Research
Published
1995-07
Volume
77
Issue
1
Pages
199-205
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2120327065
Cited by
168
References
1
FWCI
5.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Osmotic Compression of Single Cardiac Myocytes Eliminates the Reduction in Ca 2+ Sensitivity of Tension at Short Sarcomere Length. https://app.cochat.ai/papers/10.1161/01.res.77.1.199
The paper
McDonald, K. S., & Moss, R. L. (1995). Osmotic Compression of Single Cardiac Myocytes Eliminates the Reduction in Ca 2+ Sensitivity of Tension at Short Sarcomere Length. Circulation Research. https://doi.org/10.1161/01.res.77.1.199

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.