The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In Vivo Echocardiographic Detection of Enhanced Left Ventricular Function in Gene-Targeted Mice With Phospholamban Deficiency
Abstract
Abstract We evaluated the ability of M-mode and Doppler echocardiography to assess left ventricular (LV) function reliably and repeatedly in mice and tested whether these techniques could detect physiological alterations in phospholamban (PLB)–deficient mice. Anesthetized wild-type mice (n=7) and mice deficient in PLB (n=8) were studied with two-dimensional guided M-mode and Doppler echocardiography using a 9-MHz imaging and 5- to 7.5-MHz Doppler transducer. Data were acquired in the baseline state and after intraperitoneal isoproterenol administration (2.0 μg/g IP). Interobserver and intraobserver variability and reproducibility were excellent. PLB-deficient mice were associated with significant ( P <.05) increases in several physiological parameters (mean±SD) compared with wild-type control mice: normalized mean velocity of circumferential shortening (7.7±2.1 versus 5.5±1.0 circ/sec), peak aortic velocity (105±13 versus 75±9.2 cm/s), mean aortic acceleration (57±16 versus 31±4 m/s 2 ), and peak early-diastolic transmitral velocity (80.0±7.2 versus 66.9±7.7 cm/s). LV dimensions, shortening fractions, heart rates, late diastolic transmitral (A) velocities, and early to late (E/A) diastolic velocity ratios were similar in both groups. Isoproterenol administration resulted in significant increases in Doppler indices of ventricular function in control but not PLB-deficient mice. These findings indicate that assessment of LV function can be performed noninvasively in mice under varying physiological conditions and that PLB regulates basal LV function in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Kubota, T., McTiernan, C. F., Frye, C. S., Slawson, S. E., Lemster, B. H., Koretsky, A. P., Demetris, A. J., & Feldman, A. M. (1997) · Circulation Research · doi:10.1161/01.res.81.4.627 · Cited by 829
Adrenergic and Muscarinic Receptors in the Human Heart
Brodde, O.-E., & Michel, M. C. (1999) · Pharmacological Reviews · doi:10.1016/s0031-6997(24)01425-x · Cited by 673
Transgenic Gαq overexpression induces cardiac contractile failure in mice
D’Angelo, D. D., Sakata, Y., Lorenz, J. N., Boivin, G. P., Walsh, R. A., Liggett, S. B., & Dorn, G. W. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.15.8121 · Cited by 629
Self-citationModulation of Cardiac Contractility by the Phopholamban/SERCA2a Regulatome
Kranias, E. G., & Hajjar, R. J. (2012) · Circulation Research · doi:10.1161/circresaha.111.259754 · Cited by 532
Self-citationHaghighi, K., Kolokathis, F., Pater, L., Lynch, R. A., Asahi, M., Gramolini, A. O., Fan, G.-C., Tsiapras, D., Hahn, H. S., Adamopoulos, S., et al. (2003) · Journal of Clinical Investigation · doi:10.1172/jci17892 · Cited by 478
Self-citation
Metadata
- Authors
- Hoit, B. D., Khoury, S. F., Kranias, E. G., Ball, N., & Walsh, R. A.
- Venue
- Circulation Research
- Published
- 1995-09
- Volume
- 77
- Issue
- 3
- Pages
- 632-637
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2114851684
- Cited by
- 241
- References
- 1
- FWCI
- 14.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In Vivo Echocardiographic Detection of Enhanced Left Ventricular Function in Gene-Targeted Mice With Phospholamban Deficiency. https://app.cochat.ai/papers/10.1161/01.res.77.3.632
- The paper
- Hoit, B. D., Khoury, S. F., Kranias, E. G., Ball, N., & Walsh, R. A. (1995). In Vivo Echocardiographic Detection of Enhanced Left Ventricular Function in Gene-Targeted Mice With Phospholamban Deficiency. Circulation Research. https://doi.org/10.1161/01.res.77.3.632
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.