Anisotropic Activation Spread in Heart Cell Monolayers Assessed by High-Resolution Optical Mapping: Role of Tissue Discontinuities
The DOI matches its Crossref record.
Abstract
The role of tissue discontinuities in anisotropic impulse propagation was assessed in two-dimensional anisotropic monolayers of neonatal rat myocytes cultured on a growth-directing substrate of collagen. Activation spread and distribution of maximal upstroke rate of rise (V˙ max ) of the action potential were measured with an optical system using a voltage-sensitive fluorescent dye (RH-327) and a 10×10 photodiode array with a spatial resolution ranging from 7 to 15 μm. Activation maps were compared with the cellular architecture and the distribution of gap junctions obtained from immunostaining the gap junction protein connexin43 (Cx43). Four types of structures were studied: (1) dense cell cultures, (2) cultures with anisotropic intercellular clefts of variable size, (3) discontinuities created by inclusion of nonmyocyte cells, and (4) discontinuities resulting from nonuniform expression of gap junctions. In dense monolayers, activation spread was continuous with microinhomogeneities in both longitudinal and transverse directions. The average cell dimensions in such monolayers were smaller than in adult canine myocardium. However, the degree of cellular anisotropy (length-to-width ratio of 5.3±1.4) and connectivity were similar. The presence of small intercellular clefts (less than one cell in length) did not disturb the general pattern of transverse or longitudinal activation spread, but it was associated with wave front microcollisions during transverse propagation and a concomitant increase of V˙ max beyond the cleft. Long intercellular clefts caused discontinuous transverse propagation. Conduction velocity and V˙ max decreased significantly at narrow isthmuses formed by closely apposed clefts, rendering such sites susceptible for conduction block. In contrast, V˙ max increased when the wave front faced the borders of the clefts. Nonmyocyte cells were electrically connected to myocytes and served as sinks for electrotonic currents, thereby producing localized conduction slowing and a decrease in V˙ max . Localized inhomogeneity in Cx43 distribution correlated accurately with circumscribed conduction block and changes in V˙ max . Our results provide direct experimental evidence that the cellular structure and gap junction distribution correlate with action potential propagation and distribution of V˙ max . We suggest that in tissue with a nonuniform anisotropy, connective tissue separating fiber bundles or sites of inhomogeneous connexin distribution may represent predilective sites for block in transverse direction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Basic Mechanisms of Cardiac Impulse Propagation and Associated Arrhythmias
KLÉBER, A. G., & RUDY, Y. (2004) · Physiological Reviews · doi:10.1152/physrev.00025.2003 · Cited by 1,083
Self-citationShaw, R. M., & Rudy, Y. (1997) · Circulation Research · doi:10.1161/01.res.81.5.727 · Cited by 670
Nanoscale cues regulate the structure and function of macroscopic cardiac tissue constructs
Kim, D.-H., Lipke, E. A., Kim, P., Cheong, R., Thompson, S., Delannoy, M., Suh, K.-Y., Tung, L., & Levchenko, A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0906504107 · Cited by 611
Role of gap junctions in the propagation of the cardiac action potential
Rohr, S. (2004) · Cardiovascular Research · doi:10.1016/j.cardiores.2003.11.035 · Cited by 465
Cardiac muscle tissue engineering: toward an in vitro model for electrophysiological studies
Bursac, N., Papadaki, M., Cohen, R. J., Schoen, F. J., Eisenberg, S. R., Carrier, R., Vunjak-Novakovic, G., & Freed, L. E. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.277.2.h433 · Cited by 366
Metadata
- Authors
- Fast, V. G., Darrow, B. J., Saffitz, J. E., & Kle´ber, A. G.
- Venue
- Circulation Research
- Published
- 1996-07
- Volume
- 79
- Issue
- 1
- Pages
- 115-127
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2152465678
- Cited by
- 145
- References
- 0
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Anisotropic Activation Spread in Heart Cell Monolayers Assessed by High-Resolution Optical Mapping: Role of Tissue Discontinuities. https://app.cochat.ai/papers/10.1161/01.res.79.1.115
- The paper
- Fast, V. G., Darrow, B. J., Saffitz, J. E., & Kle´ber, A. G. (1996). Anisotropic Activation Spread in Heart Cell Monolayers Assessed by High-Resolution Optical Mapping: Role of Tissue Discontinuities. Circulation Research. https://doi.org/10.1161/01.res.79.1.115
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.