The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Cytoskeletal Mechanics in Pressure-Overload Cardiac Hypertrophy
Abstract
We have shown that the cellular contractile dysfunction characteristic of pressure-overload cardiac hypertrophy results not from an abnormality intrinsic to the myofilament portion of the cardiocyte cytoskeleton but rather from an increased density of the microtubule component of the extramyofilament portion of the cardiocyte cytoskeleton. To determine how, in physical terms, this increased microtubule density mechanically overloads the contractile apparatus at the cellular level, we measured cytoskeletal stiffness and apparent viscosity in isolated cardiocytes via magnetic twisting cytometry, a technique by which magnetically induced force is applied directly to the cytoskeleton through integrin-coupled ferromagnetic beads coated with Arg-Gly-Asp (RGD) peptide. Measurements were made in two groups of cardiocytes from cats with right ventricular (RV) hypertrophy induced by pulmonary artery banding: (1) those from the pressure-overloaded RV and (2) those from the normally loaded same-animal control left ventricle (LV). Cytoskeletal stiffness increased almost twofold, from 8.53±0.77 dyne/cm 2 in the normally loaded LV cardiocytes to 16.46±1.32 dyne/cm 2 in the hypertrophied RV cardiocytes. Cytoskeletal apparent viscosity increased almost fourfold, from 20.97±1.92 poise in the normally loaded LV cardiocytes to 87.85±6.95 poise in the hypertrophied RV cardiocytes. In addition to these baseline data showing differing stiffness and, especially, apparent viscosity in the two groups of cardiocytes, microtubule depolymerization by colchicine was found to return both the stiffness and the apparent viscosity of the pressure overload–hypertrophied RV cells fully to normal. Conversely, microtubule hyperpolymerization by taxol increased the stiffness and apparent viscosity values of normally loaded LV cardiocytes to the abnormal values given above for pressure-hypertrophied RV cardiocytes. Thus, increased microtubule density constitutes primarily a viscous load on the cardiocyte contractile apparatus in pressure-overload cardiac hypertrophy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Promotion of microtubule assembly in vitro by taxol
SCHIFF, P. B., FANT, J., & HORWITZ, S. B. (1979) · Nature · doi:10.1038/277665a0 · Cited by 3,600
Cited by
Molecular Mechanisms of Myocardial Remodeling
SWYNGHEDAUW, B. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.1.215 · Cited by 1,460
Tensegrity I. Cell structure and hierarchical systems biology
Ingber, D. E. (2003) · Journal of Cell Science · doi:10.1242/jcs.00359 · Cited by 1,265
Self-citationZile, M. R., & Brutsaert, D. L. (2002) · Circulation · doi:10.1161/hc1102.105289 · Cited by 1,184
Self-citationActin Binding Proteins: Regulation of Cytoskeletal Microfilaments
Dos Remedios, C. G., Chhabra, D., Kekic, M., Dedova, I. V., Tsubakihara, M., Berry, D. A., & Nosworthy, N. J. (2003) · Physiological Reviews · doi:10.1152/physrev.00026.2002 · Cited by 1,056
Zile, M. R., & Brutsaert, D. L. (2002) · Circulation · doi:10.1161/hc1202.105290 · Cited by 887
Self-citation
Metadata
- Authors
- Tagawa, H., Wang, N., Narishige, T., Ingber, D. E., Zile, M. R., & Cooper, G.
- Venue
- Circulation Research
- Published
- 1997-02
- Volume
- 80
- Issue
- 2
- Pages
- 281-289
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2116424197
- Cited by
- 179
- References
- 1
- FWCI
- 4.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cytoskeletal Mechanics in Pressure-Overload Cardiac Hypertrophy. https://app.cochat.ai/papers/10.1161/01.res.80.2.281
- The paper
- Tagawa, H., Wang, N., Narishige, T., Ingber, D. E., Zile, M. R., & Cooper, G. (1997). Cytoskeletal Mechanics in Pressure-Overload Cardiac Hypertrophy. Circulation Research. https://doi.org/10.1161/01.res.80.2.281
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.