The DOI matches its Crossref record.
Formation of the Atrioventricular Septal Structures in the Normal Mouse
Abstract
Abstract —It is sometimes thought that formation of the atrioventricular septum is equated with fusion of the endocardial cushions and that failure of fusion can explain all deficiencies of atrioventricular septation. Clearly, this is simplistic, but the exact contribution of different primordia to atrioventricular septation is not well understood. To clarify this, we studied normal mouse embryos (days 10 to 15 of gestation), which were serially sectioned and examined by light microscopy. Another group of embryos was examined by scanning electron microscopy after microdissection. Our results show that development of the atrioventricular septal area is highly complex. Proper formation requires the following: remodeling of the inner heart curvature, rotation of the horns of the systemic venous sinus around the pulmonary portal, expansion of the right atrioventricular junction, formation of the muscular atrial and ventricular septa, bridging by the dextrodorsal outflow ridge and the superior endocardial cushion, fusion with the inferior margins of the venous valves, and formation of the mouth of the coronary sinus from the cranial muscular wall of the left sinus horn. Multiple primordia contribute to a central mesenchymal mass (the “septum intermedium”), including the mesenchyme on the leading edge of the primary atrial septum, the atrioventricular endocardial cushions, and the cap of mesenchyme on the spina vestibuli. Fusion of these components closes the ostium primum, completing atrial and atrioventricular septation. Additionally, the spina vestibuli has a mesodermal core, which contributes to the muscularization of the lower margin of the oval fossa. This contrasts with the formation of the upper rim, which occurs as a result of an infolding of the atrial wall itself.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ventura, A., Young, A. G., Winslow, M. M., Lintault, L., Meissner, A., Erkeland, S. J., Newman, J., Bronson, R. T., Crowley, D., Stone, J. R., et al. (2008) · Cell · doi:10.1016/j.cell.2008.02.019 · Cited by 1,590
Brutsaert, D. L. (2003) · Physiological Reviews · doi:10.1152/physrev.00017.2002 · Cited by 697
Cyclin E Ablation in the Mouse
Geng, Y., Yu, Q., Sicinska, E., Das, M., Schneider, J. E., Bhattacharya, S., Rideout, W. M., Bronson, R. T., Gardner, H., & Sicinski, P. (2003) · Cell · doi:10.1016/s0092-8674(03)00645-7 · Cited by 660
Heart Valve Development: Regulatory Networks in Development and Disease
Combs, M. D., & Yutzey, K. E. (2009) · Circulation Research · doi:10.1161/circresaha.109.201566 · Cited by 455
Patterning the vertebrate heart
Harvey, R. P. (2002) · Nature Reviews Genetics · doi:10.1038/nrg843 · Cited by 450
Metadata
- Authors
- Webb, S., Brown, N. A., & Anderson, R. H.
- Venue
- Circulation Research
- Published
- 1998-04-06
- Volume
- 82
- Issue
- 6
- Pages
- 645-656
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2118743496
- Cited by
- 158
- References
- 0
- FWCI
- 2.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Formation of the Atrioventricular Septal Structures in the Normal Mouse. https://app.cochat.ai/papers/10.1161/01.res.82.6.645
- The paper
- Webb, S., Brown, N. A., & Anderson, R. H. (1998). Formation of the Atrioventricular Septal Structures in the Normal Mouse. Circulation Research. https://doi.org/10.1161/01.res.82.6.645
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.