CoChat

Slow Conduction in Cardiac Tissue, II: Effects of Branching Tissue Geometry

Open access
Kucera, Jan P., Kléber, André G., Rohr, Stephan · 1998 · Circulation Research
Cited by 140

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Abstract —In cardiac tissue, functional or structural current-to-load mismatches can induce local slow conduction or conduction block, which are important determinants of reentrant arrhythmias. This study tested whether spatially repetitive mismatches result in a steady-state slowing of conduction. Patterned growth of neonatal rat heart cells in culture was used to design unbranched cell strands or strands releasing branches from either a single point or multiple points at periodic intervals. Electrical activation was followed optically using voltage-sensitive dyes under control conditions and in elevated [K + ] o (5.8 and 14.8 mmol/L, respectively; in the latter case, propagation was carried by the L-type Ca 2+ current). Preparations with multiple branch points exhibited discontinuous and slow conduction that became slower with increasing branch length and/or decreasing inter-branch distance. Compared with unbranched strands, conduction was maximally slowed by 63% under control conditions (from 44.9±3.4 to 16.7±1.0 cm/s) and by 93% in elevated [K + ] o (from 15.7±2.3 to 1.1±0.2 cm/s). Local activation delays induced at a single branch point were significantly larger than the delays per branch point in multiple branching structures. Also, selective inactivation of inward currents in the branches induced conduction blocks. These 2 observations pointed to a dual role of the branches in propagation: whereas they acted as current sinks for the approaching activation thus slowing conduction (“pull” effect), they supplied, once excited, depolarizing current supporting downstream activation (“push” effect). This “pull and push” action resulted in a slowing of conduction in which the safety was largely preserved by the “push” effect. Thus, branching microarchitectures might contribute to slow conduction in tissue with discontinuous geometry, such as infarct scars and the atrioventricular node.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.83.8.795

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 140

Metadata

Authors
Kucera, J. P., Kléber, A. G., & Rohr, S.
Venue
Circulation Research
Published
1998-10-19
Volume
83
Issue
8
Pages
795-805
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2918598742
Cited by
140
References
1
FWCI
4.45
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Slow Conduction in Cardiac Tissue, II: Effects of Branching Tissue Geometry. https://app.cochat.ai/papers/10.1161/01.res.83.8.795
The paper
Kucera, J. P., Kléber, A. G., & Rohr, S. (1998). Slow Conduction in Cardiac Tissue, II: Effects of Branching Tissue Geometry. Circulation Research. https://doi.org/10.1161/01.res.83.8.795

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.