Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 331

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Examination of the Transverse Tubular System in Living Cardiac Rat Myocytes by 2-Photon Microscopy and Digital Image–Processing Techniques

Open access
Soeller, C., Cannell, M. B.·1999·Circulation Research

Abstract

Abstract —The transverse tubular system (t-system) of cardiac muscle is a structure that allows rapid propagation of excitation into the cell interior. Using 2-photon molecular excitation microscopy and digital image–processing methods, we have obtained a comprehensive overview of the t-system of rat ventricular myocytes in living cells. We show that it is possible to quantify the morphology of the t-system in terms of average local tubule diameter, branching pattern, and local abundance of the t-system by immersing living myocytes in a dextran-linked fluorescein solution. Our data suggest that previous electron microscopic examinations of t-system structure have underestimated both the geometric complexity of the t-system morphology and the fraction of cell volume occupied by the t-system (3.6% in this species). About 40% of tubules occur between Z-lines, and the t-tubule diameter is 255±0.85 nm (mean±SEM). The t-tubules leave the outer surface of the cell in an approximately rectangular array; however, at some points junctions between the t-tubules and the surface membrane are missing. In view of the complexity of the t-system apparent from our images, we propose that the t-system be renamed the “sarcolemmal Z rete.” The methods presented here are generally applicable to the quantification of the sarcolemmal Z rete and other structures within cells by fluorescence microscopy in a variety of cell types.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.84.3.266

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 331

Metadata

Authors
Soeller, C., & Cannell, M. B.
Venue
Circulation Research
Published
1999-02-19
Volume
84
Issue
3
Pages
266-275
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2023758830
Cited by
331
References
1
FWCI
7.47
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Examination of the Transverse Tubular System in Living Cardiac Rat Myocytes by 2-Photon Microscopy and Digital Image–Processing Techniques. https://app.cochat.ai/papers/10.1161/01.res.84.3.266
The paper
Soeller, C., & Cannell, M. B. (1999). Examination of the Transverse Tubular System in Living Cardiac Rat Myocytes by 2-Photon Microscopy and Digital Image–Processing Techniques. Circulation Research. https://doi.org/10.1161/01.res.84.3.266

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.