Enhanced Dispersion of Repolarization and Refractoriness in Transgenic Mouse Hearts Promotes Reentrant Ventricular Tachycardia
Open accessAbstract
Abstract —The heterogeneous distribution of ion channels in ventricular muscle gives rise to spatial variations in action potential (AP) duration (APD) and contributes to the repolarization sequence in healthy hearts. It has been proposed that enhanced dispersion of repolarization may underlie arrhythmias in diseases with markedly different causes. We engineered dominant negative transgenic mice that have prolonged QT intervals and arrhythmias due to the loss of a slowly inactivating K + current. Optical techniques are now applied to map APs and investigate the mechanisms underlying these arrhythmias. Hearts from transgenic and control mice were isolated, perfused, stained with di-4-ANEPPS, and paced at multiple sites to optically map APs, activation, and repolarization sequences at baseline and during arrhythmias. Transgenic hearts exhibited a 2-fold prolongation of APD, less shortening (8% versus 40%) of APDs with decreasing cycle length, altered restitution kinetics, and greater gradients of refractoriness from apex to base compared with control hearts. A premature impulse applied at the apex of transgenic hearts produced sustained reentrant ventricular tachycardia (n=14 of 15 hearts) that did not occur with stimulation at the base (n=8) or at any location in control hearts (n=12). In transgenic hearts, premature impulses initiated reentry by encountering functional lines of conduction block caused by enhanced dispersion of refractoriness. Reentrant VT had stable (>30 minutes) alternating long/short APDs associated with long/short cycle lengths and T wave alternans. Thus, optical mapping of genetically engineered mice may help elucidate some electrophysiological mechanisms that underlie arrhythmias and sudden death in human cardiac disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tallini, Y. N., Ohkura, M., Choi, B.-R., Ji, G., Imoto, K., Doran, R., Lee, J., Plan, P., Wilson, J., Xin, H.-B., et al. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0509378103 · Cited by 439
Self-citationEngraftment of connexin 43-expressing cells prevents post-infarct arrhythmia
Roell, W., Lewalter, T., Sasse, P., Tallini, Y. N., Choi, B.-R., Breitbach, M., Doran, R., Becher, U. M., Hwang, S.-M., Bostani, T., et al. (2007) · Nature · doi:10.1038/nature06321 · Cited by 413
Self-citationKuo, H.-C., Cheng, C.-F., Clark, R. B., Lin, J. J.-C., Lin, J. L.-C., Hoshijima, M., Nguyêñ-Trân, V. T. B., Gu, Y., Ikeda, Y., Chu, P.-H., et al. (2001) · Cell · doi:10.1016/s0092-8674(01)00588-8 · Cited by 411
Efimov, I. R., Nikolski, V. P., & Salama, G. (2004) · Circulation Research · doi:10.1161/01.res.0000130529.18016.35 · Cited by 390
Self-citationModulation of Cardiac Gap Junction Expression and Arrhythmic Susceptibility
Danik, S. B., Liu, F., Zhang, J., Suk, H. J., Morley, G. E., Fishman, G. I., & Gutstein, D. E. (2004) · Circulation Research · doi:10.1161/01.res.0000148664.33695.2a · Cited by 270
Metadata
- Authors
- Baker, L. C., London, B., Choi, B.-R., Koren, G., & Salama, G.
- Venue
- Circulation Research
- Published
- 2000-03-03
- Volume
- 86
- Issue
- 4
- Pages
- 396-407
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2137572796
- Cited by
- 176
- References
- 0
- FWCI
- 9.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced Dispersion of Repolarization and Refractoriness in Transgenic Mouse Hearts Promotes Reentrant Ventricular Tachycardia. https://app.cochat.ai/papers/10.1161/01.res.86.4.396
- The paper
- Baker, L. C., London, B., Choi, B.-R., Koren, G., & Salama, G. (2000). Enhanced Dispersion of Repolarization and Refractoriness in Transgenic Mouse Hearts Promotes Reentrant Ventricular Tachycardia. Circulation Research. https://doi.org/10.1161/01.res.86.4.396
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.