Alterations in the determinants of diastolic suction during pacing tachycardia
Open accessAbstract
Abstract —In cardiomyocytes, generation of restoring forces (RFs) responsible for elastic recoil involves deformation of the sarcomeric protein titin in conjunction with shortening below slack length. At the left ventricular (LV) level, recoil and filling by suction require contraction to an end-systolic volume (ESV) below equilibrium volume (Veq) as well as large-scale deformations, for example, torsion or twist. Little is known about RFs and suction in the failing ventricle. We undertook a comparison of determinants of suction in open-chest dogs previously subjected to 2 weeks of pacing tachycardia (PT) and controls. To assess the ability of the LV to contract below Veq, we used a servomotor to clamp left atrial pressure and produce nonfilling diastoles, allowing measurement of fully relaxed pressure at varying volumes. We quantified twist with sonomicrometry. We also assessed transmural ratios of N2B to N2BA titin isoforms and total titin to myosin heavy chain (MHC) protein. In PT, the LV did not contract below Veq, even with marked reduction of volume (end-diastolic pressure [EDP], 1 to 2 mm Hg), whereas in controls ESV was less than Veq when EDP was less than ≈5 mm Hg. In PT, both systolic twist and diastolic untwisting rate were reduced, and there was exaggerated transmural variation in titin isoform and titin-to-MHC ratios, consistent with the more extensible N2BA being present in larger amounts in the subendocardium. Thus, in PT, determinants of suction at the level of the LV are markedly impaired. The altered transmural titin isoform gradient is consistent with a decrease in RFs and may contribute to these findings.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Both compliant N2BA and stiff N2B titin isoforms are expressed in canines (N2BA:N2B ratio ~0.6-1) and humans (ratio ~0.4-1.2).
“Both compliant N2BA and stiff N2B isoforms are expressed in canines (N2BA:N2B ratio of ~ 0.6–1) and humans (N2BA:N2B ratio of ~0.4–1.2) (Bell, et al., 2000; Cazorla, et al., 2000; Jaber, et al., 2008; Makarenko, et al., 2004; Nagueh, et al., 2004).”
From Small and large animal models in cardiac contraction research: advantages and disadvantages (2014) · cites this paper as Bell, et al., 2000
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 35 · Cited by 190
Research works printed but not linked: 2
- Rademakers FE, Buchalter MB, Rogers WJ, Zerhouni EA, Weisfeldt ML, Weiss JL, Shapiro EP. Dissociation between left ventricular untwisting and filling. Circulation. 1992;85:1572-1581.
- Rozich J, Carabello B, Usher B, Kratz J, Bell A, Zile M. Mitral valve replacement with and without chordal preservation in patients with chronic mitral regurgitation. Circulation. 1992;86:1718 -1726.
- Authors
- Bell, S. P., Nyland, L., Tischler, M. D., McNabb, M., Granzier, H., & LeWinter, M. M.
- Affiliations
- University of Vermont (US)
- ORCID
- LeWinter, Martin M.
- Venue
- Circulation Research
- Published
- 2000-08-04
- Volume
- 87
- Issue
- 3
- Pages
- 235-240
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2101462306
- Cited by
- 190
- References
- 35
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 4 · 2023: 2 · 2022: 6 · 2021: 3 · 2020: 7 · 2019: 6 · 2018: 2 · 2017: 4 · 2016: 4 · 2015: 3 · 2014: 12 · 2013: 7 · 2012: 12
- FWCI
- 3.97
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Circulation Research (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01hl051201-07)
- National Heart, Lung, and Blood Institute (HL-51201, R01HL061497, HL 61497)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiomyopathy and Myosin Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- restoring force, titin isoforms, left ventricular contractility, end-systolic volume, equilibrium volume, transmural heterogeneity, left ventricular failure, myosin heavy chain
- MeSH terms
- Animals, Cardiac Pacing, Artificial, Diastole, Dogs, Elasticity, Heart Ventricles, Hemodynamics, Muscle Proteins, Myocardial Contraction, Protein Conformation, Protein Kinases, Tachycardia, Vacuum, Protein Isoforms, Connectin
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review