CoChat

Treatment of Basilar Artery Embolism With a Mechanical Extraction Device: Necessity of Flow Reversal

Open access
Mayer, Thomas E., Hamann, Gerhard F., Brueckmann, Hartmut J. · 2002 · Stroke
Cited by 109

The DOI matches its Crossref record.

Abstract

Background and Purpose— The success of local fibrinolysis in vertebrobasilar thromboembolism depends on the volume and composition of the clot. Since thrombolysis can also be time consuming and cause bleeding, we investigated the feasibility of a mechanical clot retraction device based on a nitinol basket advanced through a microcatheter. Methods— Five patients with acute embolism of the basilar artery who presented with progressive stroke and impaired consciousness were included in a multicenter study (Neuronet Evaluation in Embolic Stroke Disease [NEED]). In 3 patients flow reversal was induced with the use of silicone balloons or coaxial catheters. Three patients required additional fibrinolysis. Results— The device failed to retrieve the clots in our first 2 patients with distal basilar artery embolism. After successful recanalization by local fibrinolysis, both patients survived, 1 disabled and 1 with little residual impairment. In the next 3 patients the anterograde flow in the basilar artery was reversed during the short retraction period by temporarily blocking the vertebral or subclavian arteries. Two of these patients were completely recanalized by solely mechanical means; the third patient needed additional fibrinolysis before also being recanalized. All 3 patients survived: 1 remained disabled, 1 had almost a full recovery, and 1 became asymptomatic the day after the procedure. Conclusions— Mechanical thrombus extraction seems to be a feasible method for preventing infarction by rapid, complete, and safe recanalization of the basilar artery. We recommend the use of flow control to support retrieval of the thrombus (which the proximal flow would otherwise keep in place like a cork) and to protect the distal vessels from embolization by fragments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.0000024524.71680.c6

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 109

Metadata

Authors
Mayer, T. E., Hamann, G. F., & Brueckmann, H. J.
Venue
Stroke
Published
2002-09
Volume
33
Issue
9
Pages
2232-2235
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2129957870
Cited by
109
References
0
FWCI
7.37
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Treatment of Basilar Artery Embolism With a Mechanical Extraction Device: Necessity of Flow Reversal. https://app.cochat.ai/papers/10.1161/01.str.0000024524.71680.c6
The paper
Mayer, T. E., Hamann, G. F., & Brueckmann, H. J. (2002). Treatment of Basilar Artery Embolism With a Mechanical Extraction Device: Necessity of Flow Reversal. Stroke. https://doi.org/10.1161/01.str.0000024524.71680.c6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.