The DOI matches its Crossref record.
Remote Evaluation of Acute Ischemic Stroke: Reliability of National Institutes of Health Stroke Scale via Telestroke
Open accessAbstract
Background and Purpose— Despite Food and Drug Administration approval of tissue-type plasminogen activator for stroke, obstacles in the US healthcare system prevent its widespread use. The Remote Evaluation for Acute Ischemic Stroke (REACH) program was developed to address these issues in rural settings. A key component of stroke assessment in the REACH system is the National Institutes of Health Stroke Scale (NIHSS) evaluation. We sought to determine whether, using the REACH system, NIHSS values of bedside and remote evaluators would correspond. Methods— Twenty patients were recruited. On obtaining consent, a neurologist performed a bedside NIHSS evaluation on each patient. Within 1 hour, using any broadband-connected workstation—either office or home personal computer and a landline phone to speak with the patient—a second neurologist remotely evaluated the patient through the REACH system. Paired t tests and Pearson correlation coefficients were used to examine NIHSS reliability performed bedside and remotely. Results— NIHSS ranged from 1 to 24. Correlations between bedside and remote locations ( r =0.9552, P =0.0001) were very strong, and t tests indicate that the means were not different. Conclusions— The NIHSS can be reliably performed over the REACH system. This supports our endeavor to bring stroke expertise to rural community hospitals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidelines for Management of Ischaemic Stroke and Transient Ischaemic Attack 2008
(2008) · Cerebrovascular Diseases · doi:10.1159/000131083 · Cited by 2,489
Sacco, R. L., Adams, R., Albers, G., Alberts, M. J., Benavente, O., Furie, K., Goldstein, L. B., Gorelick, P., Halperin, J., Harbaugh, R., et al. (2006) · Stroke · doi:10.1161/01.str.0000199147.30016.74 · Cited by 1,873
Self-citationSacco, R. L., Adams, R., Albers, G., Alberts, M. J., Benavente, O., Furie, K., Goldstein, L. B., Gorelick, P., Halperin, J., Harbaugh, R., et al. (2006) · Circulation · doi:10.1161/circ.113.10.e409 · Cited by 541
Self-citationSchwamm, L. H., Holloway, R. G., Amarenco, P., Audebert, H. J., Bakas, T., Chumbler, N. R., Handschu, R., Jauch, E. C., Knight, W. A., Levine, S. R., et al. (2009) · Stroke · doi:10.1161/strokeaha.109.192360 · Cited by 449
Meyer, B. C., Raman, R., Hemmen, T., Obler, R., Zivin, J. A., Rao, R., Thomas, R. G., & Lyden, P. D. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70171-6 · Cited by 399
Metadata
- Authors
- Wang, S., Lee, S. B., Pardue, C., Ramsingh, D., Waller, J., Gross, H., Nichols, F. T., Hess, D. C., & Adams, R. J.
- Venue
- Stroke
- Published
- 2003-10
- Volume
- 34
- Issue
- 10
- Pages
- e188-91
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W1973390289
- Cited by
- 179
- References
- 0
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Remote Evaluation of Acute Ischemic Stroke: Reliability of National Institutes of Health Stroke Scale via Telestroke. https://app.cochat.ai/papers/10.1161/01.str.0000091847.82140.9d
- The paper
- Wang, S., Lee, S. B., Pardue, C., Ramsingh, D., Waller, J., Gross, H., Nichols, F. T., Hess, D. C., & Adams, R. J. (2003). Remote Evaluation of Acute Ischemic Stroke: Reliability of National Institutes of Health Stroke Scale via Telestroke. Stroke. https://doi.org/10.1161/01.str.0000091847.82140.9d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.