The DOI matches its Crossref record.
Transesophageal Echocardiography Is Superior to Transthoracic Echocardiography in Management of Patients of Any Age With Transient Ischemic Attack or Stroke
Abstract
Background and Purpose— The merits of transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) in the management of transient ischemic attack (TIA) and stroke patients remains matter of debate. Methods— Two hundred and thirty-one consecutive patients with a recent TIA or stroke for which no definite cause and indication for anticoagulation was assessed after standardized work-up underwent TTE and TEE. Echocardiographic findings were categorized into minor and major risk factors. Results— A potential cardiac source of embolism was detected in 55% (127/ 231) of the patients by echocardiography, in 39% (90/231) only identified on TEE. Major risk factors, with an absolute indication for oral anticoagulation, were detected in 20% (46/231) of the patients, in 16% (38/231) of all patients identified on TEE only. A thrombus in the left atrial appendage was the most common major risk factor (38 patients, 16%). The presence of major risk factors was independent of age (χ 2 =1.48; P =0.224). The difference in proportions of cardiac sources detected in favor of TEE was highly significant in both patients ≤45 years of age (10/39, P =0.002) and in those >45 years of age (80/192; P <0.004). Conclusions— TEE proved superior to TTE for identification of a cardiac embolic source in patients with TIA or stroke without pre-existent indication or contraindication for anticoagulation. In patients with normal TTE, a cardiac source of embolism was detected by TEE in ≈40% of patients, independent of age. More than 1 of 8 patients of any age with normal TTE revealed a major cardiac risk factor on TEE, in whom anticoagulation is warranted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Powers, W. J., Rabinstein, A. A., Ackerson, T., Adeoye, O. M., Bambakidis, N. C., Becker, K., Biller, J., Brown, M., Demaerschalk, B. M., Hoh, B., et al. (2019) · Stroke · doi:10.1161/str.0000000000000211 · Cited by 7,468
Kleindorfer, D. O., Towfighi, A., Chaturvedi, S., Cockroft, K. M., Gutierrez, J., Lombardi-Hill, D., Kamel, H., Kernan, W. N., Kittner, S. J., Leira, E. C., et al. (2021) · Stroke · doi:10.1161/str.0000000000000375 · Cited by 3,237
Guidelines for Management of Ischaemic Stroke and Transient Ischaemic Attack 2008
(2008) · Cerebrovascular Diseases · doi:10.1159/000131083 · Cited by 2,489
Easton, J. D., Saver, J. L., Albers, G. W., Alberts, M. J., Chaturvedi, S., Feldmann, E., Hatsukami, T. S., Higashida, R. T., Johnston, S. C., Kidwell, C. S., et al. (2009) · Stroke · doi:10.1161/strokeaha.108.192218 · Cited by 1,845
Guidelines for the Use of Echocardiography in the Evaluation of a Cardiac Source of Embolism
Saric, M., Armour, A. C., Arnaout, M. S., Chaudhry, F. A., Grimm, R. A., Kronzon, I., Landeck, B. F., Maganti, K., Michelena, H. I., & Tolstrup, K. (2016) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2015.09.011 · Cited by 427
Metadata
- Authors
- de Bruijn, S. F. T. M., Agema, W. R. P., Lammers, G. J., van der Wall, E. E., Wolterbeek, R., Holman, E. R., Bollen, E. L. E. M., & Bax, J. J.
- Venue
- Stroke
- Published
- 2006-10
- Volume
- 37
- Issue
- 10
- Pages
- 2531-2534
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2132077045
- Cited by
- 216
- References
- 0
- FWCI
- 9.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transesophageal Echocardiography Is Superior to Transthoracic Echocardiography in Management of Patients of Any Age With Transient Ischemic Attack or Stroke. https://app.cochat.ai/papers/10.1161/01.str.0000241064.46659.69
- The paper
- de Bruijn, S. F. T. M., Agema, W. R. P., Lammers, G. J., van der Wall, E. E., Wolterbeek, R., Holman, E. R., Bollen, E. L. E. M., & Bax, J. J. (2006). Transesophageal Echocardiography Is Superior to Transthoracic Echocardiography in Management of Patients of Any Age With Transient Ischemic Attack or Stroke. Stroke. https://doi.org/10.1161/01.str.0000241064.46659.69
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.