CoChat

Safety, Feasibility, and Short-Term Follow-Up of Drug-Eluting Stent Placement in the Intracranial and Extracranial Circulation

Open access
Gupta, Rishi, Al-Ali, Firas, Thomas, Ajith J., Horowitz, Michael B., Barrow, Thomas, Vora, Nirav A., Uchino, Ken, Hammer, Maxim D., Wechsler, Lawerence R., Jovin, Tudor G. · 2006 · Stroke
Cited by 191

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background and Purpose— The use of bare metal stents to treat symptomatic intracranial stenosis may be associated with significant restenosis rates. The advent of drug-eluting stents (DESs) in the coronary circulation has resulted in a reduction of restenosis rates. We report our technical success rate and short-term restenosis rates after stenting with DESs in the intracranial and extracranial circulation. Methods— This study was a retrospective review of the period between April 1, 2004, and April 15, 2006, of 59 patients with 62 symptomatic intracranial or extracranial atherosclerotic lesions at 2 medical centers (University of Pittsburgh and Borgess Medical Center). Results— The mean age of our cohort was 61±12 years. The location of the 62 lesions was as follows: extracranial vertebral artery 31 (50%), intracranial vertebral artery or basilar artery 18 (29%), extracranial internal carotid artery (ICA) near the petrous bone 5 (8%), and intracranial ICA 8 (13%). There were 2 (3%) periprocedural complications: 1 non—flow-limiting dissection and 1 disabling stroke. Fifty vessels were available for follow-up angiography or computed tomography angiography at a median time of 4.0±2 months. A total of 2 of 36 extracranial stents (7%) and 1 of 26 intracranial stents (5%) were found to have restenosis ≥50% at follow-up. Conclusions— This report demonstrates that DES delivery in the intracranial and extracranial circulation is technically feasible. A small percentage of patients developed short-term in-stent restenosis. Longer-term follow-up is required in the setting of a prospective study to determine the late restenosis rates for DESs in comparison with bare metal stents.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.0000242481.38262.7b

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 191

Metadata

Authors
Gupta, R., Al-Ali, F., Thomas, A. J., Horowitz, M. B., Barrow, T., Vora, N. A., Uchino, K., Hammer, M. D., Wechsler, L. R., & Jovin, T. G.
Venue
Stroke
Published
2006-10
Volume
37
Issue
10
Pages
2562-2566
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2135996219
Cited by
191
References
1
FWCI
12.34
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.