Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 168

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

The Stroke–Thrombolytic Predictive Instrument: A Predictive Instrument for Intravenous Thrombolysis in Acute Ischemic Stroke

Kent, David M., Selker, Harry P., Ruthazer, Robin, Bluhmki, Erich, Hacke, Werner·2006·Stroke

Abstract

Background and Purpose— Many patients with ischemic stroke eligible for recombinant tissue plasminogen activator (rt-PA) are not treated in part because of the risks and benefits perceived by treating physicians. Therefore, we aimed to develop a Stroke-Thrombolytic Predictive Instrument (TPI) to aid physicians considering thrombolysis for stroke. Methods— Using data from 5 major randomized clinical trials (n=2184) testing rt-PA in the 0- to 6-hour window, we developed logistic regression equations using clinical variables as potential predictors of a good outcome (modified Rankin Scale score ≤1) and of a catastrophic outcome (modified Rankin Scale score ≥5), with and without rt-PA. The models were internally validated using bootstrap re-sampling. Results— To predict good outcome, in addition to rt-PA treatment, 7 variables significantly affected prognosis and/or the treatment-effect of rt-PA: age, diabetes, stroke severity, sex, previous stroke, systolic blood pressure, and time from symptom onset. To predict catastrophic outcome, only age, stroke severity, and serum glucose were significant; rt-PA treatment was not. For patients treated within 3 hours, the median predicted probability of a good outcome with rt-PA was 42.9% (interquartile range [IQR]=18.6% to 64.7%) versus 25.3% (IQR=9.8% to 46.2%) without rt-PA; the median predicted absolute benefit was 12.5% (IQR=5.1% to 21.0%). The median probability for a catastrophic outcome, with or without, rt-PA was 15.2% (IQR=8.0% to 31.2%). The area under the receiver-operator characteristic curve was 0.788 for the model predicting good outcome and 0.775 for the model predicting bad outcome. Conclusions— The Stroke-TPI predicts good and bad functional outcomes with and without thrombolysis. Incorporated into a usable tool, it may assist in decision-making.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.0000249054.96644.c6

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 168

Metadata

Authors
Kent, D. M., Selker, H. P., Ruthazer, R., Bluhmki, E., & Hacke, W.
Venue
Stroke
Published
2006-12
Volume
37
Issue
12
Pages
2957-2962
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2139899738
Cited by
168
References
1
FWCI
3.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Stroke–Thrombolytic Predictive Instrument: A Predictive Instrument for Intravenous Thrombolysis in Acute Ischemic Stroke. https://app.cochat.ai/papers/10.1161/01.str.0000249054.96644.c6
The paper
Kent, D. M., Selker, H. P., Ruthazer, R., Bluhmki, E., & Hacke, W. (2006). The Stroke–Thrombolytic Predictive Instrument: A Predictive Instrument for Intravenous Thrombolysis in Acute Ischemic Stroke. Stroke. https://doi.org/10.1161/01.str.0000249054.96644.c6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.