The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Measuring carotid stenosis. Time for a reappraisal.
Abstract
Data from recent multicenter carotid endarterectomy trials have questioned the validity and reliability of Doppler ultrasound in the assessment of carotid stenosis. We prospectively analyzed 45 patients undergoing carotid angiography to compare the North American Symptomatic Carotid Endarterectomy Trial (NASCET) and European Carotid Surgery Trial (ECST) methods of measuring carotid stenosis with those of direct visualization ("eyeballing") and duplex ultrasound. Linear NASCET and ECST measurements were also converted into area using the pi r2 function and termed "squared NASCET" (N2) and "squared ECST" (E2). In 15 of 45 patients undergoing carotid endarterectomy, the carotid plaque was removed intact, sectioned, and photographed for computer measurement of cross-sectional area. Comparison of this "gold standard" was then made to each method of measurement. Comparison between duplex and the various angiographic measurement techniques revealed significant differences between NASCET and duplex (P < .0001), ECST and duplex (P < .01), and E2 and duplex (P < .01) but not between N2, eyeballing, and carotid duplex methods. Even the NASCET and ECST methods themselves differed significantly (P < .006). When comparison was made with computerized planimetric measurements of the carotid plaque, there were significant differences for both NASCET (P < .0007) and ECST (P < .007). Correlation was demonstrated only between planimetry and N2, E2, and duplex. NASCET and ECST angiographic methods of measurement consistently underestimate the "true" anatomic stenosis. As such, they represent only "indexes" of carotid stenosis severity. Duplex provides a more accurate measurement of carotid stenosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Beneficial Effect of Carotid Endarterectomy in Symptomatic Patients with High-Grade Carotid Stenosis
(1991) · New England Journal of Medicine · doi:10.1056/nejm199108153250701 · Cited by 8,368
Cited by
Biller, J., Feinberg, W. M., Castaldo, J. E., Whittemore, A. D., Harbaugh, R. E., Dempsey, R. J., Caplan, L. R., Kresowik, T. F., Matchar, D. B., Toole, J. F., et al. (1998) · Stroke · doi:10.1161/01.str.29.2.554 · Cited by 658
Grading Carotid Stenosis Using Ultrasonic Methods
von Reutern, G.-M., Goertler, M.-W., Bornstein, N. M., Sette, M. D., Evans, D. H., Goertler, M.-W., Hetzel, A., Kaps, M., Perren, F., Razumovky, A., et al. (2012) · Stroke · doi:10.1161/strokeaha.111.636084 · Cited by 337
Metadata
- Authors
- Alexandrov, A. V., Bladin, C. F., Maggisano, R., & Norris, J. W.
- Venue
- Stroke
- Published
- 1993-09
- Volume
- 24
- Issue
- 9
- Pages
- 1292-1296
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2054015990
- Cited by
- 193
- References
- 1
- FWCI
- 19.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measuring carotid stenosis. Time for a reappraisal. https://app.cochat.ai/papers/10.1161/01.str.24.9.1292
- The paper
- Alexandrov, A. V., Bladin, C. F., Maggisano, R., & Norris, J. W. (1993). Measuring carotid stenosis. Time for a reappraisal. Stroke. https://doi.org/10.1161/01.str.24.9.1292
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.