Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 202

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Accuracy and Prognostic Consequences of Ultrasonography in Identifying Severe Carotid Artery Stenosis

Eliasziw, M., Rankin, R.N., Fox, A.J., Haynes, R.B., Barnett, H.J.M.·1995·Stroke

Abstract

Background and Purpose The accuracy of routine ultrasonography in detecting severe carotid artery stenosis was evaluated in comparison with cerebral angiography. The precision of ultrasonographic criteria in predicting the risk of stroke was also assessed. Methods A total of 1011 symptomatic carotid bifurcations were studied in patients from the North American Symptomatic Carotid Endarterectomy Trial (NASCET). Given that all patients were considered for entry into the trial, the chance of a verification bias affecting the analyses was minimized. The ultrasonographic data consisted of peak systolic velocities and frequency changes from both the internal and common carotid arteries. Angiographic stenosis was calculated as in NASCET. Receiver operating characteristic (ROC) curves were constructed from the ultrasonographic data for the detection of 70% or greater stenosis on the basis of an angiographic assessment. Kaplan-Meier stroke-free survival curves were used to predict the risk of stroke. Results The areas under the ROC curves ranged from 0.74 to 0.75 (95% confidence interval [CI], 0.69 to 0.79). The sensitivities and specificities ranged from 0.65 to 0.71. The risk of stroke at 18 months declined sharply as the degree of angiographically defined stenosis declined from 99% to 70%. No pattern of decline was apparent on the basis of the ultrasonographic data. Conclusions The results indicate that the accuracy of ultrasonography is moderate when flow parameters are used to assess the degree of stenosis. Ultrasonography should be used as a screening tool to exclude patients with no carotid artery disease from further testing. Conventional angiography remains an essential investigation before assigning the risk of stroke and deciding appropriate treatment for extracranial carotid artery disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.26.10.1747

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 202

Metadata

Authors
Eliasziw, M., Rankin, R. N., Fox, A. J., Haynes, R. B., & Barnett, H. J. M.
Venue
Stroke
Published
1995-10
Volume
26
Issue
10
Pages
1747-1752
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W1998666376
Cited by
202
References
2
FWCI
10.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy and Prognostic Consequences of Ultrasonography in Identifying Severe Carotid Artery Stenosis. https://app.cochat.ai/papers/10.1161/01.str.26.10.1747
The paper
Eliasziw, M., Rankin, R. N., Fox, A. J., Haynes, R. B., & Barnett, H. J. M. (1995). Accuracy and Prognostic Consequences of Ultrasonography in Identifying Severe Carotid Artery Stenosis. Stroke. https://doi.org/10.1161/01.str.26.10.1747

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.