Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 188

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Preoperative Assessment of the Carotid Bifurcation: Can Magnetic Resonance Angiography and Duplex Ultrasonography Replace Contrast Arteriography?

Patel, Mahesh R., Kuntz, Karen M., Klufas, Roman A., Kim, Ducksoo, Kramer, Jonathan, Polak, Joseph F., Skillman, John J., Whittemore, Anthony D., Edelman, Robert R., Kent, K. Craig·1995·Stroke

Abstract

Background and Purpose Noninvasive studies are used with increasing frequency to assess the carotid bifurcation before endarterectomy. Therefore, assessment of their diagnostic accuracies is essential for appropriate patient management. We prospectively evaluate two noninvasive tests, magnetic resonance angiography (MRA) and duplex ultrasonography (DU), as potential replacements for contrast arteriography (CA). Methods A blinded comparison of three-dimensional time-of-flight (TOF) MRA, two-dimensional TOF MRA, and DU in 176 arteries was performed. CA was used as the standard of comparison. Results Three-dimensional TOF MRA had a sensitivity of 94%, a specificity of 85%, and an accuracy of 88% for the identification of 70% to 99% stenosis; two-dimensional TOF MRA had a sensitivity and specificity that were approximately 10% lower than those of three-dimensional TOF MRA. DU resulted in a sensitivity of 94%, a specificity of 83%, and an accuracy of 86%. Combining data from three-dimensional TOF MRA and DU, allowing for CA only for disparate results, yielded a sensitivity of 100%, a specificity of 91%, and an accuracy of 94% among concordant noninvasive tests, with CA required in 16% of arteries. MRA accurately differentiated 17 carotid occlusions from 16 high-grade (90% to 99%) stenoses, whereas with DU two patent arteries were identified as occluded and one occluded artery was identified as patent. Conclusions Three-dimensional TOF MRA is the most accurate noninvasive test. Combined use of MRA and DU results in a marked increase in accuracy to a level that obviates the need for CA in a majority of patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.26.10.1753

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 188

Metadata

Authors
Patel, M. R., Kuntz, K. M., Klufas, R. A., Kim, D., Kramer, J., Polak, J. F., Skillman, J. J., Whittemore, A. D., Edelman, R. R., & Kent, K. C.
Venue
Stroke
Published
1995-10
Volume
26
Issue
10
Pages
1753-1758
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W1992658552
Cited by
188
References
1
FWCI
8.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Preoperative Assessment of the Carotid Bifurcation: Can Magnetic Resonance Angiography and Duplex Ultrasonography Replace Contrast Arteriography? https://app.cochat.ai/papers/10.1161/01.str.26.10.1753
The paper
Patel, M. R., Kuntz, K. M., Klufas, R. A., Kim, D., Kramer, J., Polak, J. F., Skillman, J. J., Whittemore, A. D., Edelman, R. R., & Kent, K. C. (1995). Preoperative Assessment of the Carotid Bifurcation: Can Magnetic Resonance Angiography and Duplex Ultrasonography Replace Contrast Arteriography? Stroke. https://doi.org/10.1161/01.str.26.10.1753

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.