Helical CT for the Diagnosis of Extracranial Internal Carotid Artery Dissection
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background and Purpose We attempted to evaluate the sensitivity of helical CT for the diagnosis of extracranial internal carotid artery (ICA) dissection. Methods Sixteen consecutive patients with 18 angiographically confirmed extracranial ICA dissections were studied with a helical CT protocol with large-volume acquisition and thin axial slice reconstructions. A control group including normal and atherosclerotic ICAs was formed for comparison, and a blind interpretation of CT images was made by two observers. We evaluated the presence of stenosis, eccentric lumen, mural thickening, aneurysm, occlusion, and annular contrast enhancement. When the artery seemed to be occluded, we measured the external diameter of the ICA (1) on the occluded side, at its upper portion and most enlarged level, (2) at its lower portion, beyond the bulb, and (3) on the contralateral side, at its upper portion. Results Interobserver agreement was good except for the presence of annular contrast enhancement. In the stenotic dissection group (n=12), the presence of a narrowed eccentric lumen at the upper portion of the ICA on axial CT images was classified correctly in all cases (sensitivity, 100%; specificity, 100%). An arterial wall thickening was seen in all cases of dissection but also in three cases of the control group. In the occlusive dissection group (n=6), the enlargement of the dissected artery was the best criterion (sensitivity, 100%, specificity, 100%) for occlusive dissection. Conclusions Helical CT seems to be a reliable method for evaluating extracranial ICA dissection. The analysis of the residual arterial lumen and the measurement of the external diameter of the carotid artery were the best criteria for the diagnosis. Further studies with larger groups are required to determine whether ICA dissections might be diagnosed using helical CT as a first procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring nominal scale agreement among many raters.
Fleiss, J. L. (1971) · Psychological Bulletin · doi:10.1037/h0031619 · Cited by 8,733
Cited by
Spontaneous Dissection of the Carotid and Vertebral Arteries
Schievink, W. I. (2001) · New England Journal of Medicine · doi:10.1056/nejm200103223441206 · Cited by 1,575
Cervical-artery dissections: predisposing factors, diagnosis, and outcome
Debette, S., & Leys, D. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(09)70084-5 · Cited by 833
Self-citation
Metadata
- Authors
- Leclerc, X., Godefroy, O., Salhi, A., Lucas, C., Leys, D., & Pruvo, J. P.
- Venue
- Stroke
- Published
- 1996-03
- Volume
- 27
- Issue
- 3
- Pages
- 461-466
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2052602563
- Cited by
- 170
- References
- 1
- FWCI
- 8.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.