A New Automated Computerized Analyzing System Simplifies Readings and Reduces the Variability in Ultrasound Measurement of Intima-Media Thickness
Abstract
Background and Purpose A computerized analyzing system with manual tracing of echo interfaces for measurement of intima-media thickness and lumen diameter in carotid and femoral arteries was previously developed by our research group and has been used for many years in several laboratories. However, manual measurements are not only time consuming, but the results from these readings are also dependent on training and subjective judgement. A further problem is the observed drift in measurements over time. A new computerized technique for automatic detection of echo interfaces was therefore developed. The aim of this study was to evaluate the new automated computerized analyzing system. Methods The new system is based on dynamic programming and includes optional interactive modification by the human operator. Local measurements of vessel echo intensity, intensity gradient, and boundary continuity are extracted by image analysis techniques and included as weighed terms in a cost function. The dynamic programming procedure is used for determining the optimal location of the vessel interfaces in a way that the cost function is minimized. Results With the new automated computerized analyzing system the measurement results were less dependent on the reader’s experience, and the variability between readers was less compared with the old manual analyzing system. The measurements were also less time consuming. Conclusions The new automated analyzing system will not only greatly increase the speed of measurements but also reduce the variability between readers. It should also reduce the variability between different laboratories if the same analyzing program is used. Furthermore, the new system will probably prevent the problem with drift in measurements over time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bellman, R. E., & Dreyfus, S. E. (1962) · Princeton University Press eBooks · doi:10.1515/9781400874651 · Cited by 1,971
Furberg, C. D., Adams, H. P., Applegate, W. B., Byington, R. P., Espeland, M. A., Hartwell, T., Hunninghake, D. B., Lefkowitz, D. S., Probstfield, J., & Riley, W. A. (1994) · Circulation · doi:10.1161/01.cir.90.4.1679 · Cited by 867
Ultrasound B-mode imaging in observational studies of atherosclerotic progression.
SALONEN, J. T., & Salonen, R. M. (1993) · PubMed · Cited by 783
Pravastatin, lipids, and atherosclerosis in the carotid arteries (PLAC-II)
Crouse, J. R., Byington, R. P., Bond, M. G., Espefand, M. A., Craven, T. E., Sprinkle, J. W., McGovern, M. E., & Furberg, C. D. (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80580-3 · Cited by 609
Wendelhag, I., Gustavsson, T., Suurküla, M., Berglund, G., & Wikstrand, J. (1991) · Clinical Physiology · doi:10.1111/j.1475-097x.1991.tb00676.x · Cited by 515
Self-citationBlankenhorn, D. H., Selzer, R. H., Crawford, D. W., Barth, J. D., Liu, C. R., Liu, C. H., Mack, W. J., & Alaupovic, P. (1993) · Circulation · doi:10.1161/01.cir.88.1.20 · Cited by 384
Selzer, R. H., Hodis, H. N., Kwong-Fu, H., Mack, W. J., Lee, P. L., Liu, C.-R., & Liu, C.-H. (1994) · Atherosclerosis · doi:10.1016/0021-9150(94)90186-4 · Cited by 300
Use of monitoring software to improve the measurement of carotid wall thickness by B-mode imaging
Touboul, P.-J., Prati, P., Scarabin, P.-Y., Adrai, V., Thibout, E., & Ducimetière, P. (1992) · Journal of Hypertension · doi:10.1097/00004872-199207001-00006 · Cited by 186
Bots, M. L., Hofman, A., de Bruyn, A. M., de Jong, P. T., & Grobbee, D. E. (1993) · Arteriosclerosis and Thrombosis: A Journal of Vascular Biology · doi:10.1161/01.atv.13.1.64 · Cited by 171
Gariepy, J., Massonneau, M., Levenson, J., Heudes, D., & Simon, A. (1993) · Hypertension · doi:10.1161/01.hyp.22.1.111 · Cited by 167
Cited by
Stein, J. H., Korcarz, C. E., Hurst, R. T., Lonn, E., Kendall, C. B., Mohler, E. R., Najjar, S. S., Rembold, C. M., & Post, W. S. (2008) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2007.11.011 · Cited by 2,429
American Society of Echocardiography recommendations for use of echocardiography in clinical trials
Gottdiener, J. S., Bednarz, J., Devereux, R., Gardin, J., Klein, A., Manning, W. J., Morehead, A., Kitzman, D., Oh, J., Quinones, M., et al. (2004) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2004.07.013 · Cited by 902
Nyström, T., Gutniak, M. K., Zhang, Q., Zhang, F., Holst, J. J., Ahrén, B., & Sjöholm, Å. (2004) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00237.2004 · Cited by 680
Urbina, E. M., Williams, R. V., Alpert, B. S., Collins, R. T., Daniels, S. R., Hayman, L., Jacobson, M., Mahoney, L., Mietus-Snyder, M., Rocchini, A., et al. (2009) · Hypertension · doi:10.1161/hypertensionaha.109.192639 · Cited by 641
Bots, M. L., Evans, G. W., Riley, W. A., & Grobbee, D. E. (2003) · Stroke · doi:10.1161/01.str.0000102044.27905.b5 · Cited by 379
Metadata
- Authors
- Wendelhag, I., Liang, Q., Gustavsson, T., & Wikstrand, J.
- Venue
- Stroke
- Published
- 1997-11
- Volume
- 28
- Issue
- 11
- Pages
- 2195-2200
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2127523891
- Cited by
- 375
- References
- 14
- FWCI
- 10.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A New Automated Computerized Analyzing System Simplifies Readings and Reduces the Variability in Ultrasound Measurement of Intima-Media Thickness. https://app.cochat.ai/papers/10.1161/01.str.28.11.2195
- The paper
- Wendelhag, I., Liang, Q., Gustavsson, T., & Wikstrand, J. (1997). A New Automated Computerized Analyzing System Simplifies Readings and Reduces the Variability in Ultrasound Measurement of Intima-Media Thickness. Stroke. https://doi.org/10.1161/01.str.28.11.2195
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.