Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 375

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

A New Automated Computerized Analyzing System Simplifies Readings and Reduces the Variability in Ultrasound Measurement of Intima-Media Thickness

Wendelhag, Inger, Liang, Quan, Gustavsson, Tomas, Wikstrand, John·1997·Stroke

Abstract

Background and Purpose A computerized analyzing system with manual tracing of echo interfaces for measurement of intima-media thickness and lumen diameter in carotid and femoral arteries was previously developed by our research group and has been used for many years in several laboratories. However, manual measurements are not only time consuming, but the results from these readings are also dependent on training and subjective judgement. A further problem is the observed drift in measurements over time. A new computerized technique for automatic detection of echo interfaces was therefore developed. The aim of this study was to evaluate the new automated computerized analyzing system. Methods The new system is based on dynamic programming and includes optional interactive modification by the human operator. Local measurements of vessel echo intensity, intensity gradient, and boundary continuity are extracted by image analysis techniques and included as weighed terms in a cost function. The dynamic programming procedure is used for determining the optimal location of the vessel interfaces in a way that the cost function is minimized. Results With the new automated computerized analyzing system the measurement results were less dependent on the reader’s experience, and the variability between readers was less compared with the old manual analyzing system. The measurements were also less time consuming. Conclusions The new automated analyzing system will not only greatly increase the speed of measurements but also reduce the variability between readers. It should also reduce the variability between different laboratories if the same analyzing program is used. Furthermore, the new system will probably prevent the problem with drift in measurements over time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.28.11.2195

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 375

Metadata

Authors
Wendelhag, I., Liang, Q., Gustavsson, T., & Wikstrand, J.
Venue
Stroke
Published
1997-11
Volume
28
Issue
11
Pages
2195-2200
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2127523891
Cited by
375
References
14
FWCI
10.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A New Automated Computerized Analyzing System Simplifies Readings and Reduces the Variability in Ultrasound Measurement of Intima-Media Thickness. https://app.cochat.ai/papers/10.1161/01.str.28.11.2195
The paper
Wendelhag, I., Liang, Q., Gustavsson, T., & Wikstrand, J. (1997). A New Automated Computerized Analyzing System Simplifies Readings and Reduces the Variability in Ultrasound Measurement of Intima-Media Thickness. Stroke. https://doi.org/10.1161/01.str.28.11.2195

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.