Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 487

The DOI matches its Crossref record.

Reliability of the National Institutes of Health Stroke Scale: Extension to Non-Neurologists in the Context of a Clinical Trial

Goldstein, Larry B., Samsa, Gregory P.·1997·Stroke

Abstract

Background and Purpose The reliability of the National Institutes of Health Stroke Scale (NIHSS) has been established through testing its use in live and videotaped patients. This reliability testing has primarily focused on the use of the scale by neurologists. We sought to determine the reliability of the NIHSS as used by non-neurologists in the context of a clinical trial. Methods In anticipation of the initiation of a randomized trial of a new therapy for patients with acute ischemic stroke, 30 physician investigators (30% of whom were not neurologists) and 29 non-physician study coordinators were trained in the use of the NIHSS at an informational and training conference using standardized videotaped patient examinations. A series of 4 patients were rated initially. After 3 months, the same 4 patients were rerated, providing a measure of intraobserver reliability. An additional series of 4 new patients were also rated after 3 months and, with the initial 4 ratings, provided data for assessment of interobserver reliability. Results Overall, 28% of the raters had previous experience with the NIHSS, and 22% had previously used the videotapes as used in the present trial. The coefficients of determination ( r 2 ) were each greater than .95 when the means of the two ratings of the same 4 cases were compared between (1) neurologists and other types of physicians, (2) physicians and study coordinators, (3) raters who had prior experience with the NIHSS and those without prior experience, and (4) raters who had used the videotapes in the past and those who had never viewed the tapes. The calculated r 2 s were greater than .98 for the initial rating of the first 4 cases and for the later rating of the 4 new cases. The slopes of the regression lines were all near 1, indicating that the raters were similarly calibrated. The intraclass correlation coefficients were .93 and .95, reflecting high levels of intraobserver and interobserver reliability. Conclusions These data extend the previously demonstrated reliability of the NIHSS to non-neurologists and show that both a variety of physician investigators and nurse study coordinators can be rapidly trained to reliably apply the scale in the context of an actual clinical trial.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.28.2.307

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 487

Metadata

Authors
Goldstein, L. B., & Samsa, G. P.
Venue
Stroke
Published
1997-02
Volume
28
Issue
2
Pages
307-310
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W1996442299
Cited by
487
References
0
FWCI
3.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability of the National Institutes of Health Stroke Scale: Extension to Non-Neurologists in the Context of a Clinical Trial. https://app.cochat.ai/papers/10.1161/01.str.28.2.307
The paper
Goldstein, L. B., & Samsa, G. P. (1997). Reliability of the National Institutes of Health Stroke Scale: Extension to Non-Neurologists in the Context of a Clinical Trial. Stroke. https://doi.org/10.1161/01.str.28.2.307

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.