CoChat

Relationship Between Prothrombin Activation Fragment F1.2 and International Normalized Ratio in Patients With Atrial Fibrillation

Feinberg, William M., Cornell, Elaine S., Nightingale, Sarah D., Pearce, Lesly A., Tracy, Russell P., Hart, Robert G., Bovill, Edwin G. · 1997 · Stroke
Cited by 107

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background and Purpose The prothrombin time (expressed as the international normalized ratio [INR]) is the standard method of monitoring warfarin therapy in patients with atrial fibrillation. Prothrombin activation fragment F1.2 provides an index of in vivo thrombin generation and might provide a better index of the effective intensity of anticoagulation. We examined the relationship between F1.2 and INR in patients with atrial fibrillation. Methods We measured INR and F1.2 levels in 846 patients with atrial fibrillation participating in the Stroke Prevention in Atrial Fibrillation III study. Two hundred nineteen (26%) were taking aspirin alone, 326 (39%) were taking adjusted-dose warfarin, and 301 (36%) were taking a low fixed dose of warfarin (1 to 3 mg) plus aspirin (combination therapy). F1.2 levels were measured with an enzyme-linked immunosorbent assay. Results Patients receiving adjusted-dose warfarin or combination therapy had significantly higher INR and significantly lower F1.2 values than those on aspirin alone ( P ≤.0001 for each of the four comparisons). F1.2 values (nanomolar) were inversely correlated with INR (F1.2=−0.1+2.3[1/INR]; R 2 =.37; P <.0001; simple linear regression). However, significant variability remained. Among patients receiving warfarin, older patients had higher F1.2 values than younger patients after adjustment for INR intensity ( P <.001) in the model. There was no difference in the relationship between F1.2 and INR between men and women. Conclusions Increasing intensity of anticoagulation, as measured by the INR, is associated with decreasing thrombin generation as measured by the F1.2 level, but significant variability exists in this relationship. Older anticoagulated patients have higher F1.2 values than younger patients at equivalent INR values. The clinical significance of these differences is not clear. F1.2 measurement might provide information regarding anticoagulation intensity in addition to that reflected by the INR.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.28.6.1101

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Feinberg, W. M., Cornell, E. S., Nightingale, S. D., Pearce, L. A., Tracy, R. P., Hart, R. G., & Bovill, E. G.
Venue
Stroke
Published
1997-06
Volume
28
Issue
6
Pages
1101-1106
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2025985576
Cited by
107
References
1
FWCI
3.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.