Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 201

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Grading of Cerebral Dynamic Autoregulation From Spontaneous Fluctuations in Arterial Blood Pressure

Panerai, Ronney B., White, Richard P., Markus, Hugh S., Evans, David H. · 1998 · Stroke

Abstract

Background and Purpose —Assessment of cerebral autoregulation has been traditionally performed with static changes in arterial blood pressure. Newer dynamic methods require the induction of sudden drops in arterial blood pressure with the sudden release of bilateral thigh cuffs. An alternative method is proposed, based on the spontaneous variability of arterial blood pressure that does not require its manipulation. We compared this method with the established thigh cuff method in patients with carotid artery stenosis. Methods —Cerebral blood flow velocity (determined by transcranial Doppler) and arterial blood pressure (determined by noninvasive servo-controlled plethysmograph) were recorded in 20 patients with carotid artery stenosis and 18 age-matched controls. At rest, grading of dynamic autoregulation was estimated from the impulse response of the blood pressure–velocity dynamic relationship. This was compared with the autoregulatory index (ARI) provided by the thigh cuff method and with the degree of stenosis. The critical closing pressure was derived from the fitted models and was also correlated with degree of stenosis. Results —The 2 ARIs were significantly correlated ( r =0.76) and reduced in subjects with carotid stenosis (baseline ARI, 3.65±3.11 versus 6.68±1.88, P <0.0001; thigh cuff ARI, 3.78±2.32 versus 6.35±1.06, P <10 −5 ). The critical closing pressure (relative to mean arterial blood pressure) was also significantly reduced (−0.24±1.06 versus 0.50±0.31, P <0.0001) and correlated with the thigh cuff ARI ( r =0.68). Both the baseline ARI and critical closing pressure were correlated with degree of stenosis ( P <10 −6 ). Conclusions —Grading of dynamic autoregulation with the use of undisturbed recordings of arterial blood pressure and cerebral blood flow velocity might provide a safer technique for assessment of patients in whom a sudden drop of arterial blood pressure is not desirable, such as patients with heart or autonomic failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.29.11.2341

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 201

Metadata

Authors
Panerai, R. B., White, R. P., Markus, H. S., & Evans, D. H.
Venue
Stroke
Published
1998-11
Volume
29
Issue
11
Pages
2341-2346
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2153170287
Cited by
201
References
1
FWCI
5.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Grading of Cerebral Dynamic Autoregulation From Spontaneous Fluctuations in Arterial Blood Pressure. https://app.cochat.ai/papers/10.1161/01.str.29.11.2341
The paper
Panerai, R. B., White, R. P., Markus, H. S., & Evans, D. H. (1998). Grading of Cerebral Dynamic Autoregulation From Spontaneous Fluctuations in Arterial Blood Pressure. Stroke. https://doi.org/10.1161/01.str.29.11.2341

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.