CoChat

Dynamic Behavior of Heart Rate in Ischemic Stroke

Korpelainen, Juha T., Sotaniemi, Kyösti A., Mäkikallio, Anne, Huikuri, Heikki V., Myllylä, Vilho V. · 1999 · Stroke
Cited by 141

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background and Purpose —Traditional spectral and nonspectral methods have shown that heart rate (HR) variability is reduced after stroke. Some patients with poor outcome, however, show randomlike, complex patterns of HR behavior that traditional analysis techniques are unable to quantify. Therefore, we designed the present study to evaluate the complexity and correlation properties of HR dynamics after stroke by using new analysis methods based on nonlinear dynamics and fractals (“chaos theory”). Methods —In addition to the traditional spectral components of HR variability, we measured instantaneous beat-to-beat variability and long-term continuous variability analyzed from Poincaré plots, fractal correlation properties, and approximate entropy of R-R interval dynamics from 24-hour ambulatory ECG recordings in 30 healthy control subjects, 31 hemispheric stroke patients, and 15 brain stem stroke patients (8 medullary, 7 pontine) in the acute phase of stroke and 6 months after stroke. Results —In the acute phase, the traditional spectral components of HR variability and the long-term continuous variability from Poincaré plots were impaired ( P <0.01) in patients with hemispheric and medullary brain stem stroke, but not in patients with pontine brain stem stroke, in comparison with control subjects. At 6 months after stroke, measures of HR variability in hemispheric stroke patients were still lower ( P <0.05) than those of the control subjects. Various complexity and fractal measures of HR variability were similar in patients and control subjects. The conventional frequency domain measures of HR variability as well as the Poincaré measures showed strong correlations (Pearson correlation coefficient, r =0.68 to r =0.90) with each other but only weak correlations ( r =0.09 to r =0.56) with the complexity and fractal measures of HR variability. Conclusions —Hemispheric and medullary brain stem infarctions seem to damage the cardiovascular autonomic regulatory system and appear as abnormalities in the magnitude of HR variability. These abnormalities can be more easily detected with the use of analysis methods of HR variability, which are based on moment statistics, than by methods based on nonlinear dynamics. Abnormal HR variability may be involved in prognostically unfavorable cardiac complications and other known manifestations of autonomic failure associated with stroke.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.30.5.1008

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Korpelainen, J. T., Sotaniemi, K. A., Mäkikallio, A., Huikuri, H. V., & Myllylä, V. V.
Venue
Stroke
Published
1999-05
Volume
30
Issue
5
Pages
1008-1013
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2119260859
Cited by
141
References
3
FWCI
3.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.