Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 717

The DOI matches its Crossref record.

MRI Measures of Middle Cerebral Artery Diameter in Conscious Humans During Simulated Orthostasis

Open access
Serrador, Jorge M., Picot, Paul A., Rutt, Brian K., Shoemaker, J. Kevin, Bondar, Roberta L.·2000·Stroke

Abstract

Background and Purpose —The relationship between middle cerebral artery (MCA) flow velocity (CFV) and cerebral blood flow (CBF) is uncertain because of unknown vessel diameter response to physiological stimuli. The purpose of this study was to directly examine the effect of a simulated orthostatic stress (lower body negative pressure [LBNP]) as well as increased or decreased end-tidal carbon dioxide partial pressure (P ET CO 2 ) on MCA diameter and CFV. Methods —Twelve subjects participated in a CO 2 manipulation protocol and/or an LBNP protocol. In the CO 2 manipulation protocol, subjects breathed room air (normocapnia) or 6% inspired CO 2 (hypercapnia), or they hyperventilated to ≈25 mm Hg P ET CO 2 (hypocapnia). In the LBNP protocol, subjects experienced 10 minutes each of −20 and −40 mm Hg lower body suction. CFV and diameter of the MCA were measured by transcranial Doppler and MRI, respectively, during the experimental protocols. Results —Compared with normocapnia, hypercapnia produced increases in both P ET CO 2 (from 36±3 to 40±4 mm Hg, P <0.05) and CFV (from 63±4 to 80±6 cm/s, P <0.001) but did not change MCA diameters (from 2.9±0.3 to 2.8±0.3 mm). Hypocapnia produced decreases in both P ET CO 2 (24±2 mm Hg, P <0.005) and CFV (43±7 cm/s, P <0.001) compared with normocapnia, with no change in MCA diameters (from 2.9±0.3 to 2.9±0.4 mm). During −40 mm Hg LBNP, P ET CO 2 was not changed, but CFV (55±4 cm/s) was reduced from baseline (58±4 cm/s, P <0.05), with no change in MCA diameter. Conclusions —Under the conditions of this study, changes in MCA diameter were not detected. Therefore, we conclude that relative changes in CFV were representative of changes in CBF during the physiological stimuli of moderate LBNP or changes in P ET CO 2 .

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.31.7.1672

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 717

Metadata

Authors
Serrador, J. M., Picot, P. A., Rutt, B. K., Shoemaker, J. K., & Bondar, R. L.
Venue
Stroke
Published
2000-07
Volume
31
Issue
7
Pages
1672-1678
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2044192936
Cited by
717
References
0
FWCI
18.03
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MRI Measures of Middle Cerebral Artery Diameter in Conscious Humans During Simulated Orthostasis. https://app.cochat.ai/papers/10.1161/01.str.31.7.1672
The paper
Serrador, J. M., Picot, P. A., Rutt, B. K., Shoemaker, J. K., & Bondar, R. L. (2000). MRI Measures of Middle Cerebral Artery Diameter in Conscious Humans During Simulated Orthostasis. Stroke. https://doi.org/10.1161/01.str.31.7.1672

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.