Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 468

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

A Modified National Institutes of Health Stroke Scale for Use in Stroke Clinical Trials: Preliminary Reliability and Validity

Open access
Lyden, Patrick D., Lu, Mei, Levine, Steven R., Brott, Thomas G., Broderick, Joseph·2001·Stroke

Abstract

Background and Purpose —The National Institutes of Health Stroke Scale (NIHSS) is accepted widely for measuring acute stroke deficits in clinical trials, but it contains items that exhibit poor reliability or do not contribute meaningful information. To improve the scale for use in clinical research, we used formal clinimetric analyses to derive a modified version, the mNIHSS. We then sought to demonstrate the validity and reliability of the new mNIHSS. Methods —The mNIHSS was derived from our prior clinimetric studies of the NIHSS by deleting poorly reproducible or redundant items (level of consciousness, face weakness, ataxia, dysarthria) and collapsing the sensory item into 2 responses. Reliability of the mNIHSS was assessed with the certification data originally collected to assess the reliability of investigators in the National Institute of Neurological Disorders and Stroke (NINDS) rtPA (recombinant tissue plasminogen activator) Stroke Trial. Validity of the mNIHSS was assessed with the outcome results of the NINDS rtPA Stroke Trial. Results —Reliability was improved with the mNIHSS: the number of scale items with poor κ coefficients on either of the certification tapes decreased from 8 (20%) to 3 (14%) with the mNIHSS. With the use of factor analysis, the structure underlying the mNIHSS was found identical to the original scale. On serial use of the scale, goodness of fit coefficients were higher with the mNIHSS. With data from part I of the trial data, the proportion of patients who improved ≥4 points within 24 hours after treatment was statistically significantly increased by tPA (odds ratio, 1.3; 95% confidence limits, 1.0, 1.8; P =0.05). Likewise, the odds ratio for complete/nearly complete resolution of stroke symptoms 3 months after treatment was 1.7 (95% confidence limits, 1.2, 2.6) with the mNIHSS. Other outcomes showed the same agreement when the mNIHSS was compared with the original scale. The mNIHSS showed good responsiveness, ie, was useful in differentiating patients likely to hemorrhage or have a good outcome after stroke. Conclusions —The mNIHSS appears to be identical clinimetrically to the original NIHSS when the same data are used for validation and reliability. Power appears to be greater with the mNIHSS with the use of 24-hour end points, suggesting the need for fewer patients in trials designed to detect treatment effects comparable to rtPA. The mNIHSS contains fewer items and might be simpler to use in clinical research trials. Prospective analysis of reliability and validity, with the use of an independently collected cohort, must be obtained before the mNIHSS is used in a research setting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.32.6.1310

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 39 references

Cited by

See all 468

Metadata

Authors
Lyden, P. D., Lu, M., Levine, S. R., Brott, T. G., & Broderick, J.
Venue
Stroke
Published
2001-06
Volume
32
Issue
6
Pages
1310-1317
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2073249703
Cited by
468
References
39
FWCI
4.04
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Modified National Institutes of Health Stroke Scale for Use in Stroke Clinical Trials: Preliminary Reliability and Validity. https://app.cochat.ai/papers/10.1161/01.str.32.6.1310
The paper
Lyden, P. D., Lu, M., Levine, S. R., Brott, T. G., & Broderick, J. (2001). A Modified National Institutes of Health Stroke Scale for Use in Stroke Clinical Trials: Preliminary Reliability and Validity. Stroke. https://doi.org/10.1161/01.str.32.6.1310

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.