Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 237

The DOI matches its Crossref record.

Imaging the Endothelial Glycocalyx In Vitro by Rapid Freezing/Freeze Substitution Transmission Electron Microscopy

Open access
Ebong, Eno E., Macaluso, Frank P., Spray, David C., Tarbell, John M.·2011·Arteriosclerosis, Thrombosis, and Vascular Biology

Abstract

Objective—: Recent publications questioned the validity of endothelial cell (EC) culture studies of glycocalyx (GCX) function because of findings that GCX in vitro may be substantially thinner than GCX in vivo. The assessment of thickness differences is complicated by GCX collapse during dehydration for traditional electron microscopy. We measured in vitro GCX thickness using rapid freezing/freeze substitution (RF/FS) transmission electron microscopy (TEM), taking advantage of the high spatial resolution provided by TEM and the capability to stably preserve the GCX in its hydrated configuration by RF/FS. Methods and Results—: Bovine aortic EC (BAEC) and rat fat pad EC were subjected to conventional or RF/FS-TEM. Conventionally preserved BAEC GCX was ≈0.040 μm in thickness. RF/FS-TEM revealed impressively thick BAEC GCX of ≈11 μm and rat fat pad EC GCX of ≈5 μm. RF/FS-TEM also discerned GCX structure and thickness variations due to heparinase III enzyme treatment and extracellular protein removal, respectively. Immunoconfocal studies confirmed that the in vitro GCX is several micrometers thick and is composed of extensive and well-integrated heparan sulfate, hyaluronic acid, and protein layers. Conclusion—: New observations by RF/FS-TEM reveal substantial GCX layers on cultured EC, supporting their continued use for fundamental studies of GCX and its function in the vasculature.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/atvbaha.111.225268

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 237

Metadata

Authors
Ebong, E. E., Macaluso, F. P., Spray, D. C., & Tarbell, J. M.
Venue
Arteriosclerosis, Thrombosis, and Vascular Biology
Published
2011-08
Volume
31
Issue
8
Pages
1908-1915
ISSN
  • 1079-5642 (ISSN-L)
  • 1524-4636
OpenAlex
W2152934519
Cited by
237
References
0
FWCI
5.31
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Imaging the Endothelial Glycocalyx In Vitro by Rapid Freezing/Freeze Substitution Transmission Electron Microscopy. https://app.cochat.ai/papers/10.1161/atvbaha.111.225268
The paper
Ebong, E. E., Macaluso, F. P., Spray, D. C., & Tarbell, J. M. (2011). Imaging the Endothelial Glycocalyx In Vitro by Rapid Freezing/Freeze Substitution Transmission Electron Microscopy. Arteriosclerosis, Thrombosis, and Vascular Biology. https://doi.org/10.1161/atvbaha.111.225268

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.