Objective—: Cellular microparticles (MP) are promising biomarkers in many pathological situations. Although flow cytometry (FCM) is widely used for their measurement, it has raised controversies because the smallest MP size falls below the detection limit of standard FCM (sd-FCM). Following recent technological improvements leading to high sensitivity FCM (hs-FCM), our objectives were (1) to evaluate the potential of hs-FCM for extended MP detection, (2) to set up a standardized protocol for MP enumeration, and (3) to compare MP counts obtained with both sensitivity levels. Methods and Results—: Compared with sd-FCM, hs-FCM displayed improved forward scatter resolution and lower background noise, allowing us to discriminate previously undetectable small MP in plasma samples. Using fluorescent beads with appropriate sizes (0.1/0.3/0.5/0.9 μm) and relative amounts, a new standardized hs-FCM MP protocol was set up and provided reproducible MP counts. Applied to coronary patient samples, it resulted into 8- to 20-fold increases in MP counts as compared with sd-FCM. Interestingly, the ratio between small and large MP varied according to clinical status but also depending on MP subset, suggesting access to new biological information. Conclusion—: Recent improvements in FCM provide access to previously undetectable MP and represent a new opportunity to enhance their impact as biomarkers in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Witwer, K. W., Buzás, E. I., Bemis, L. T., Bora, A., Lässer, C., Lötvall, J., Nolte‐‘t Hoen, E. N., Piper, M. G., Sivaraman, S., Skog, J., et al. (2013) · Journal of Extracellular Vesicles · doi:10.3402/jev.v2i0.20360 · Cited by 2,421
Classification, Functions, and Clinical Relevance of Extracellular Vesicles
van der Pol, E., Böing, A. N., Harrison, P., Sturk, A., & Nieuwland, R. (2012) · Pharmacological Reviews · doi:10.1124/pr.112.005983 · Cited by 1,754
Arraud, N., Linares, R., Tan, S., Gounou, C., Pasquet, J. ‐., Mornet, S., & Brisson, A. R. (2014) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12554 · Cited by 740
The Methods of Choice for Extracellular Vesicles (EVs) Characterization
Szatanek, R., Baj-Krzyworzeka, M., Zimoch, J., Lekka, M., Siedlar, M., & Baran, J. (2017) · International Journal of Molecular Sciences · doi:10.3390/ijms18061153 · Cited by 563
Platelet function tests: a comparative review
Paniccia, R., Priora, R., Alessandrello Liotta, A., & Abbate, R. (2015) · Vascular Health and Risk Management · doi:10.2147/vhrm.s44469 · Cited by 505
Metadata
- Authors
- Robert, S., Lacroix, R., Poncelet, P., Harhouri, K., Bouriche, T., Judicone, C., Wischhusen, J., Arnaud, L., & Dignat-George, F.
- Venue
- Arteriosclerosis, Thrombosis, and Vascular Biology
- Published
- 2012-04
- Volume
- 32
- Issue
- 4
- Pages
- 1054-1058
- ISSN
- 1079-5642 (ISSN-L)
- 1524-4636
- OpenAlex
- W2137246476
- Cited by
- 163
- References
- 0
- FWCI
- 7.32
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Sensitivity Flow Cytometry Provides Access to Standardized Measurement of Small-Size Microparticles—Brief Report. https://app.cochat.ai/papers/10.1161/atvbaha.111.244616
- The paper
- Robert, S., Lacroix, R., Poncelet, P., Harhouri, K., Bouriche, T., Judicone, C., Wischhusen, J., Arnaud, L., & Dignat-George, F. (2012). High-Sensitivity Flow Cytometry Provides Access to Standardized Measurement of Small-Size Microparticles—Brief Report. Arteriosclerosis, Thrombosis, and Vascular Biology. https://doi.org/10.1161/atvbaha.111.244616
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.