Low-Level Vagosympathetic Stimulation: A Paradox and Potential New Modality for the Treatment of Focal Atrial Fibrillation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background— We used high-frequency stimulation delivered during the refractory period of the atrium and pulmonary veins (PVs) to induce focal firing and atrial fibrillation (AF). This study was designed to demonstrate that bilateral low-level vagosympathetic nerve stimulation (LL-VNS) could suppress high-frequency stimulation-induced focal AF at atrial and PV sites. Methods and Results— In 23 dogs anesthetized with Na-pentobarbital, electrodes in the vagosympathetic trunks allowed LL-VNS at 1 V below that which slowed the sinus rate or atrioventricular conduction. Multielectrode catheters were fixed at the right and left superior and inferior PVs and both atrial appendages. LL-VNS continued for 3 hours. At the end of each hour, the high-frequency stimulation algorithm consisting of a 40-ms train of stimuli (200 Hz; stimulus duration, 0.1 to 1.0 ms) was delivered 2 ms after the atrial pacing stimulus during the refractory period at each PV and atrial appendages site. The lowest voltage of high-frequency stimulation that induced AF was defined as the AF threshold. Five dogs without LL-VNS served as sham controls. Six dogs underwent LL-VNS after transection of bilateral vagosympathetic trunks. LL-VNS induced a progressive increase in AF threshold at all PV and atrial appendages sites, particularly significant ( P <0.05) at the right superior PV, right inferior PV, left superior PV, and right atrial appendage. Bilateral vagosympathetic transection did not significantly alter the previous findings, and the 5 sham control dogs did not show changes in AF threshold at any site over a period of 3 hours. Conclusions— LL-VNS may prevent episodic AF caused by rapid PV and non-PV firing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vanoli, E., De Ferrari, G. M., Stramba-Badiale, M., Hull, S. S., Foreman, R. D., & Schwartz, P. J. (1991) · Circulation Research · doi:10.1161/01.res.68.5.1471 · Cited by 681 · cited 1×
“There are reports in the basic literature (7, 8) as well as clinical reports (9, 10) suggesting that vagal activation can be anti-arrhythmic.”
Background
Cited by
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Role of the Autonomic Nervous System in Modulating Cardiac Arrhythmias
Shen, M. J., & Zipes, D. P. (2014) · Circulation Research · doi:10.1161/circresaha.113.302549 · Cited by 867
Role of the Autonomic Nervous System in Atrial Fibrillation: Pathophysiology and Therapy
Chen, P.-S., Chen, L. S., Fishbein, M. C., Lin, S.-F., & Nattel, S. (2014) · Circulation Research · doi:10.1161/circresaha.114.303772 · Cited by 790
Metadata
- Authors
- Li, S., Scherlag, B. J., Yu, L., Sheng, X., Zhang, Y., Ali, R., Dong, Y., Ghias, M., & Po, S. S.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2009-12
- Volume
- 2
- Issue
- 6
- Pages
- 645-651
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2155839723
- Cited by
- 122
- References
- 1
- FWCI
- 4.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.