The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Circumferential Pulmonary Vein Ablation With Additional Linear Ablation Results in an Increased Incidence of Left Atrial Flutter Compared With Segmental Pulmonary Vein Isolation as an Initial Approach to Ablation of Paroxysmal Atrial Fibrillation
Open accessAbstract
Background—: There has been growing concern that linear ablation is associated with an increased risk of iatrogenic arrhythmias in patients undergoing ablation for atrial fibrillation (AF). Therefore, we compared circumferential pulmonary vein ablation plus left atrial linear ablation (CPVA+LALA) with segmental pulmonary vein isolation (PVI)in patients with paroxysmal AF. Methods and Results—: Sixty-six consecutive patients with paroxysmal AF were prospectively randomly assigned to receive PVI versus CPVA+LALA (consisting of encircling lesions around the pulmonary veins), a roof line, and a mitral isthmus line with documentation of bidirectional mitral isthmus block. All patients were seen at 1, 3, 6, and every 12 months after ablation, with 14-day continuous ECG monitoring every 6 months. At 16.4±6.3 months after 1 ablation procedure, 19 patients (58%) remained free of atrial arrhythmias after PVI versus 17 patients (51%) after CPVA+LALA ( P =0.62). After PVI, 14 patients had recurrent paroxysmal AF, whereas after CPVA+LALA, 8 patients had recurrent AF, 6 had atypical left atrial flutter (LAFL), and 2 had both AF and LAFL ( P =0.32 between PVI versus CPVA+LALA for AF but P =0.002 for LAFL). Twenty-eight patients (85%) remained arrhythmia-free after 1.3±0.5 PVI procedures versus 28 patients (85%) after 1.4±0.6 CPVA+LALA procedures ( P =NS). Fluoroscopy time was longer after CPVA+LALA versus PVI (91 versus 73 minutes, P =0.04). Conclusions—: As an initial ablation approach in patients with paroxysmal AF, more LAFL occurred after CPVA+LALA and fluoroscopy times were longer compared with segmental PVI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atrial Tachycardia After Circumferential Pulmonary Vein Ablation of Atrial Fibrillation
Chae, S., Oral, H., Good, E., Dey, S., Wimmer, A., Crawford, T., Wells, D., Sarrazin, J.-F., Chalfoun, N., Kuhne, M., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.07.044 · Cited by 355
Peri-mitral atrial flutter in patients with atrial fibrillation ablation
Matsuo, S., Wright, M., Knecht, S., Nault, I., Lellouche, N., Lim, K.-T., Arantes, L., O'Neill, M. D., Hocini, M., Jaïs, P., et al. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2009.09.067 · Cited by 153
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Approaches to catheter ablation for persistent atrial fibrillation
Verma, A., Jiang, C.-Y., Betts, T. R., Chen, J., Deisenhofer, I., Mantovan, R., Macle, L., Morillo, C. A., Haverkamp, W., Weerasooriya, R., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1408288 · Cited by 2,339
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Metadata
- Authors
- Sawhney, N., Anousheh, R., Chen, W., & Feld, G. K.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2010-06
- Volume
- 3
- Issue
- 3
- Pages
- 243-248
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2111522813
- Cited by
- 247
- References
- 2
- FWCI
- 11.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Circumferential Pulmonary Vein Ablation With Additional Linear Ablation Results in an Increased Incidence of Left Atrial Flutter Compared With Segmental Pulmonary Vein Isolation as an Initial Approach to Ablation of Paroxysmal Atrial Fibrillation. https://app.cochat.ai/papers/10.1161/circep.109.924878
- The paper
- Sawhney, N., Anousheh, R., Chen, W., & Feld, G. K. (2010). Circumferential Pulmonary Vein Ablation With Additional Linear Ablation Results in an Increased Incidence of Left Atrial Flutter Compared With Segmental Pulmonary Vein Isolation as an Initial Approach to Ablation of Paroxysmal Atrial Fibrillation. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.109.924878
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.