The DOI matches its Crossref record.
Inhibition of Small-Conductance Ca 2+ -Activated K + Channels Terminates and Protects Against Atrial Fibrillation
Open accessAbstract
Background—: Recently, evidence has emerged that small-conductance Ca 2+ -activated K + (SK) channels are predominantly expressed in the atria in a number of species including human. In rat, guinea pig, and rabbit ex vivo and in vivo models of atrial fibrillation (AF), we used 3 different SK channel inhibitors, UCL1684, N -(pyridin-2-yl)-4-(pyridin-2-yl)thiazol-2-amine (ICA), and NS8593, to assess the hypothesis that pharmacological inhibition of SK channels is antiarrhythmic. Methods and Results—: In isolated, perfused guinea pig hearts, AF could be induced in all control hearts (n=7) with a combination of 1 μmol/L acetylcholine combined with electric stimulation. Pretreatment with 3 μmol/L NS8593, which had no effect on QT interval, prolonged the atrial effective refractory period by 37.1±7.7% ( P <0.001) and prevented acetylcholine-induced AF ( P <0.001, n=7). After AF induction, perfusion with NS8593 (10 μmol/L), UCL1684 (1 μmol/L), or ICA (1 μmol/L) terminated AF in all hearts, comparable to 10 μmol/L amiodarone. In isolated, perfused rat hearts, AF was induced with electric stimulation; 10 μmol/L NS8593 terminated AF and prevented reinduction of AF in all hearts (n=6, P <0.001). In all hearts, AF could be reinduced after washing. In isolated, perfused rabbit hearts, AF was induced with 10 μmol/L acetylcholine and burst pacing; 10 μmol/L NS8593 terminated AF and prevented reinduction of AF in all hearts (n=6, P <0.001). After washing, AF could be reinduced in 75% of the hearts (n=4, P =0.06). In an in vivo rat model of acute AF induced by burst pacing, injection of 5 mg/kg of either NS8593 or amiodarone shortened AF duration significantly to (23.2±20.0%, P <0.001, n=5, and 26.2±17.9%, P <0.001, n=5, respectively) as compared with injection of vehicle (96.3±33.2%, n=5). Conclusions—: Inhibition of SK channels prolongs atrial effective refractory period without affecting QT interval and prevents and terminates AF ex vivo and in vivo, thus offering a promising new therapeutic opportunity in the treatment of AF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pathophysiological mechanisms of atrial fibrillation: a translational appraisal
Schotten, U., Verheule, S., Kirchhof, P., & Goette, A. (2011) · Physiological Reviews · doi:10.1152/physrev.00031.2009 · Cited by 1,273
Doctoral Dissertation: The transient outward potassium current in healthy and diseased hearts
Calloe, K. (2019) · Acta Physiologica · doi:10.1111/apha.13225 · Cited by 993
Recent advances in the molecular pathophysiology of atrial fibrillation
Wakili, R., Voigt, N., Kääb, S., Dobrev, D., & Nattel, S. (2011) · Journal of Clinical Investigation · doi:10.1172/jci46315 · Cited by 545
Voigt, N., Heijman, J., Wang, Q., Chiang, D. Y., Li, N., Karck, M., Wehrens, X. H. T., Nattel, S., & Dobrev, D. (2014) · Circulation · doi:10.1161/circulationaha.113.006641 · Cited by 445
Metadata
- Authors
- Diness, J. G., Sørensen, U. S., Nissen, J. D., Al-Shahib, B., Jespersen, T., Grunnet, M., & Hansen, R. S.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2010-08
- Volume
- 3
- Issue
- 4
- Pages
- 380-390
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2548555003
- Cited by
- 189
- References
- 0
- FWCI
- 10.22
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inhibition of Small-Conductance Ca 2+ -Activated K + Channels Terminates and Protects Against Atrial Fibrillation. https://app.cochat.ai/papers/10.1161/circep.110.957407
- The paper
- Diness, J. G., Sørensen, U. S., Nissen, J. D., Al-Shahib, B., Jespersen, T., Grunnet, M., & Hansen, R. S. (2010). Inhibition of Small-Conductance Ca 2+ -Activated K + Channels Terminates and Protects Against Atrial Fibrillation. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.110.957407
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.