CoChat

Primary Prevention of Sudden Cardiac Death in Silent Cardiac Sarcoidosis: Role of Programmed Ventricular Stimulation

Open access
Mehta, Davendra, Mori, Neil, Goldbarg, Seth H., Lubitz, Steven, Wisnivesky, Juan P., Teirstein, Alvin · 2011 · Circulation: Arrhythmia and Electrophysiology
Cited by 150

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background—: Cardiac involvement in sarcoidosis is often silent and may lead to sudden death. This study was designed to assess the value of programmed electric stimulation of the ventricle (PES) for risk stratification in patients with sarcoidosis and evidence of preclinical cardiac involvement on imaging studies. Methods and Results—: Patients with biopsy-proven systemic sarcoidosis but without cardiac symptoms who had evidence of cardiac sarcoidosis on positron emission tomography (PET) or cardiac MRI (CMR) were included. All patients underwent baseline evaluation, echocardiographic assessment of left ventricular function, and programmed electric stimulation of the ventricle. Patients were followed for survival and arrhythmic events. Seventy-six patients underwent PES of the ventricle. Eight (11%) were inducible for sustained ventricular arrhythmias and received an implantable defibrillator. None of the noninducible patients received a defibrillator. Left ventricular ejection fraction was lower in patients with inducible ventricular arrhythmia (36.4±4.2% versus 55.8±1.5%, P <0.05). Over a median follow-up of 5 years, 6 of 8 patients in the group with inducible ventricular arrhythmias had ventricular arrhythmia or died, compared with 1 death in the negative group ( P <0.0001). Conclusions—: In patients with biopsy-proven sarcoidosis and evidence of cardiac involvement on PET or CMR alone, positive PES may help to identify patients at risk for ventricular arrhythmia. More importantly, patients in this cohort with a negative PES appear to have a benign course within the first several years following diagnosis. PES may help to guide the use of implantable cardioverter defibrillators in this population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.110.958322

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 150

Metadata

Authors
Mehta, D., Mori, N., Goldbarg, S. H., Lubitz, S., Wisnivesky, J. P., & Teirstein, A.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2011-02
Volume
4
Issue
1
Pages
43-48
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2141716415
Cited by
150
References
3
FWCI
5.33
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.