Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 198

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

MRI-Guided Ventricular Tachycardia Ablation: Integration of Late Gadolinium-Enhanced 3D Scar in Patients With Implantable Cardioverter-Defibrillators

Open access
Dickfeld, Timm, Tian, Jing, Ahmad, Ghada, Jimenez, Alejandro, Turgeman, Aharon, Kuk, Richard, Peters, Matthew, Saliaris, Anastasios, Saba, Magdi, Shorofsky, Stephen, Jeudy, Jean · 2011 · Circulation: Arrhythmia and Electrophysiology

Abstract

Background—: Substrate-guided ablation of ventricular tachycardia (VT) in patients with implanted cardioverter-defibrillators (ICDs) relies on voltage mapping to define the scar and border zone. An integrated 3D scar reconstruction from late gadolinium enhancement (LGE) MRI could facilitate VT ablations. Methods and Results—: Twenty-two patients with ICD underwent contrast-enhanced cardiac MRI with a specific absorption rate of <2.0 W/kg before VT ablation. Device interrogation demonstrated unchanged ICD parameters immediately before, after, or at 68±21 days follow-up ( P >0.05). ICD imaging artifacts were most prominent in the anterior wall and allowed full and partial assessment of LGE in 9±4 and 12±3 of 17 segments, respectively. In 14 patients with LGE, a 3D scar model was reconstructed and successfully registered with the clinical mapping system (accuracy, 3.9±1.8 mm). Using receiver operating characteristic curves, bipolar and unipolar voltages of 1.49 and 4.46 mV correlated best with endocardial MRI scar. Scar visualization allowed the elimination of falsely low voltage recordings (suboptimal catheter contact) in 4.1±1.9% of <1.5-mV mapping points. Display of scar border zone allowed identification of excellent pace mapping sites, with only limited voltage mapping in 64% of patients. Viable endocardium of >2 mm resulted in >1.5-mV voltage recordings despite up to 63% transmural midmyocardial scar successfully ablated with MRI guidance. All successful ablation sites demonstrated LGE (transmurality, 68±26%) and were located within 10 mm of transition zones to 0% to 25% scar in 71%. Conclusions—: Contrast-enhanced cardiac MRI can be safely performed in selected patients with ICDs and allows the integration of detailed 3D scar maps into clinical mapping systems, providing supplementary anatomic guidance to facilitate substrate-guided VT ablations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.110.958744

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 198

Metadata

Authors
Dickfeld, T., Tian, J., Ahmad, G., Jimenez, A., Turgeman, A., Kuk, R., Peters, M., Saliaris, A., Saba, M., Shorofsky, S., & Jeudy, J.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2011-04
Volume
4
Issue
2
Pages
172-184
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2557006958
Cited by
198
References
2
FWCI
11.07
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MRI-Guided Ventricular Tachycardia Ablation: Integration of Late Gadolinium-Enhanced 3D Scar in Patients With Implantable Cardioverter-Defibrillators. https://app.cochat.ai/papers/10.1161/circep.110.958744
The paper
Dickfeld, T., Tian, J., Ahmad, G., Jimenez, A., Turgeman, A., Kuk, R., Peters, M., Saliaris, A., Saba, M., Shorofsky, S., & Jeudy, J. (2011). MRI-Guided Ventricular Tachycardia Ablation: Integration of Late Gadolinium-Enhanced 3D Scar in Patients With Implantable Cardioverter-Defibrillators. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.110.958744

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.