Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 177

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Intraventricular Conduction Delay in a Standard 12-Lead Electrocardiogram as a Predictor of Mortality in the General Population

Aro, Aapo L., Anttonen, Olli, Tikkanen, Jani T., Junttila, M. Juhani, Kerola, Tuomas, Rissanen, Harri A., Reunanen, Antti, Huikuri, Heikki V. · 2011 · Circulation: Arrhythmia and Electrophysiology

Abstract

Background—: Prolonged duration of QRS complex in a 12-lead ECG is associated with adverse prognosis in patients with cardiac disease, but its significance is not well established in the general population. In particular, there is a paucity of data on the prognostic significance of nonspecific intraventricular conduction delay in apparently healthy subjects. Methods and Results—: We evaluated the 12-lead ECGs of 10 899 Finnish middle-aged subjects from the general population (52% of whom were men; mean age 44±8.5 years) between 1966 and 1972 and followed them for 30±11 years. Primary end points were all-cause mortality, cardiac mortality, and arrhythmic death. Prolonged QRS duration was defined as QRS ≥110 ms and intraventricular conduction delay as QRS ≥110 ms, without the criteria of complete or incomplete bundle-branch block. QRS duration ≥110 ms was present in 1.3% (n=147) and intraventricular conduction delay in 0.6% (n=67) of the subjects. Prolonged QRS duration predicted all-cause mortality (multivariate-adjusted relative risk [RR] 1.48; 95% confidence interval [CI] 1.22–1.81; P <0.001), cardiac mortality (RR 1.94; CI 1.44–2.63; P <0.001), and sudden arrhythmic death (RR 2.14; CI 1.38–3.33; P =0.002). Subjects with intraventricular conduction delay had increased all-cause mortality (RR 2.01; CI 1.52–2.66; P <0.001), increased cardiac mortality (RR 2.53; CI 1.64–3.90; P <0.001), and an elevated risk of arrhythmic death (RR 3.11; CI 1.74–5.54; P =0.001). Left bundle-branch block also weakly predicted arrhythmic death ( P =0.04), but right bundle-branch block was not associated with increased mortality. Conclusions—: Prolonged QRS duration in a standard 12-lead ECG is associated with increased mortality in a general population, with intraventricular conduction delay being most strongly associated with an increased risk of arrhythmic death.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.111.963561

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 177

Metadata

Authors
Aro, A. L., Anttonen, O., Tikkanen, J. T., Junttila, M. J., Kerola, T., Rissanen, H. A., Reunanen, A., & Huikuri, H. V.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2011-10
Volume
4
Issue
5
Pages
704-710
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2125526059
Cited by
177
References
2
FWCI
8.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intraventricular Conduction Delay in a Standard 12-Lead Electrocardiogram as a Predictor of Mortality in the General Population. https://app.cochat.ai/papers/10.1161/circep.111.963561
The paper
Aro, A. L., Anttonen, O., Tikkanen, J. T., Junttila, M. J., Kerola, T., Rissanen, H. A., Reunanen, A., & Huikuri, H. V. (2011). Intraventricular Conduction Delay in a Standard 12-Lead Electrocardiogram as a Predictor of Mortality in the General Population. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.111.963561

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.