Koyak, Zeliha, de Groot, Joris R., Van Gelder, Isabelle C., Bouma, Berto J., van Dessel, Pascal F.H.M., Budts, Werner, van Erven, Lieselot, van Dijk, Arie P.J., Wilde, Arthur A.M., Pieper, Petronella G., Sieswerda, Gertjan T., Mulder, Barbara J.M. · 2012 · Circulation: Arrhythmia and Electrophysiology
Cited by 85

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Background—: The value of implantable cardioverter defibrillators (ICDs) in adults with congenital heart disease (CHD) is unknown. We investigated the long-term outcome after ICD implantation and developed a simple risk stratification score for ICD therapy. Methods and Results—: A total of 136 adults with CHD and ICD (mean age±SD, 41±13 years; 67% male) were identified from 10 tertiary referral centers in the Netherlands and Belgium. The indication for ICD implantation was primary prevention in 50% of patients. Diagnoses included tetralogy of Fallot (51%), septal defects (20%), (congenitally corrected) transposition of the great arteries (13%), and other (16%). Thirty-nine patients (29%) received appropriate ICD shocks during a median follow-up of 4.6 years. Secondary prevention indication (hazard ratio [HR], 3.6; 95% CI, 1.3–9.5; P= 0.009), coronary artery disease (HR, 2.7; 95% CI, 1.0–7.2; P= 0.042), and symptomatic nonsustained ventricular tachycardia (NSVT; HR, 9.1; 95% CI, 2.8–29.2; P= 0.001) were associated with appropriate ICD shocks. A risk score was developed to evaluate the likelihood of appropriate ICD shocks. The 8-year survival curve to first appropriate shocks was 94%, 57%, and 26% for low-, intermediate-, and high-risk patients, respectively. In primary prevention, symptomatic NSVTs (HR, 8.0; 95% CI, 2.3–27.1; P= 0.001) and subpulmonary ventricular dysfunction (HR, 3.0; 95% CI, 1.2–12.6; P =0.02) were associated with appropriate shocks in univariable analysis. Inappropriate shocks occurred in 41 patients (30%). In addition, 40 patients (29%) experienced 45 implantation-related complications. Conclusions—: Adults with CHD and ICDs receive high rates of appropriate and effective shocks. Patients with secondary prevention indication, coronary artery disease, and symptomatic NSVT are at highest risk of receiving appropriate ICD shocks. ICD implantation is accompanied by considerable morbidity, including inappropriate shocks and procedure- related complications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.111.966754

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 85

Metadata

Authors
Koyak, Z., de Groot, J. R., Van Gelder, I. C., Bouma, B. J., van Dessel, P. F. H. M., Budts, W., van Erven, L., van Dijk, A. P. J., Wilde, A. A. M., Pieper, P. G., Sieswerda, G. T., & Mulder, B. J. M.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2012-02
Volume
5
Issue
1
Pages
101-110
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2110198700
Cited by
85
References
5
FWCI
5.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.