CoChat

A Randomized Study of Cardiac Resynchronization Therapy Defibrillator Versus Dual-Chamber Implantable Cardioverter-Defibrillator in Ischemic Cardiomyopathy With Narrow QRS: The NARROW-CRT Study

Open access
Muto, Carmine, Solimene, Francesco, Gallo, Paolo, Nastasi, Maurizio, La Rosa, Concetto, Calvanese, Raimondo, Iengo, Raffaele, Canciello, Michelangelo, Sangiuolo, Raffaele, Diemberger, Igor, Ciardiello, Carmine, Tuccillo, Bernardino · 2013 · Circulation: Arrhythmia and Electrophysiology
Cited by 45

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background—: Current recommendations require a QRS duration of ≥120 ms as a condition for prescribing cardiac resynchronization therapy (CRT). This study was designed to test the hypothesis that patients with heart failure (HF) of ischemic origin, current indications for defibrillator implantation, and QRS <120 ms may benefit from CRT in the presence of marked mechanical dyssynchrony. Methods and Results—: Patients with intraventricular dyssynchrony on echocardiography were randomly assigned to CRT or dual-chamber defibrillator implantation (CRT defibrillator and dual-chamber implantable cardioverter-defibrillator arm, respectively). The primary end point was the HF clinical composite response, which scores patients as improved, unchanged, or worsened. The secondary end point was the cumulative survival from HF hospitalization and HF death. An additional secondary end point was the composite of HF hospitalization, HF death, and spontaneous ventricular fibrillation. Twenty-three of 56 patients with CRT defibrillator showed an improvement in their clinical composite response at 1 year, compared with 9 of 55 patients with dual-chamber implantable cardioverter-defibrillator (41% versus 16%; P =0.004). After a median follow-up of 16 months, the CRT defibrillator arm showed a nonsignificant higher survival from HF hospitalization and HF death ( P =0.077), and a significantly higher survival from the combined end point of HF hospitalization, HF death, and spontaneous ventricular fibrillation ( P =0.028). Conclusions—: In this comparison of CRT defibrillator and dual-chamber implantable cardioverter-defibrillator, CRT improved clinical status in some patients with ischemic cardiomyopathy, mild-to-moderate symptoms, narrow QRS duration, and mechanical dyssynchrony on echocardiography. Clinical Trial Registration—: URL: http://clinicaltrials.gov . Unique identifier: NCT01577446.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.113.000135

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 45

Metadata

Authors
Muto, C., Solimene, F., Gallo, P., Nastasi, M., La Rosa, C., Calvanese, R., Iengo, R., Canciello, M., Sangiuolo, R., Diemberger, I., Ciardiello, C., & Tuccillo, B.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2013-06
Volume
6
Issue
3
Pages
538-545
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2119484408
Cited by
45
References
2
FWCI
5.08
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.