CoChat

Contemporary Outcomes of Supraventricular Tachycardia Ablation in Congenital Heart Disease: A Single-Center Experience in 116 Patients

Open access
Ueda, Akiko, Suman-Horduna, Irina, Mantziari, Lilian, Gujic, Marko, Marchese, Procolo, Ho, Siew Yen, Babu-Narayan, Sonya V., Ernst, Sabine · 2013 · Circulation: Arrhythmia and Electrophysiology
Cited by 105

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background—: Remote magnetic navigation–guided ablation with 3-dimensional (3D)-image integration could provide maximum benefit in patients with complex anatomy. We reviewed supraventricular tachycardia (SVT) ablation in adult patients with congenital heart disease to assess the contribution of these technologies. Methods and Results—: One hundred fifty-four SVT ablation procedures (228 SVTs) using a 3D-electroanatomic mapping system in 116 adult patients with congenital heart disease (mean age, 41; 76 male) were classified into 3 groups: Group A, manual mapping/ablation (n=60 procedures); Group B, remote magnetic navigation–guided mapping/ablation with normal femoral vein access (49); and Group C, remote magnetic navigation–guided mapping/ablation with difficult access (45). Group A included simple anomalies with less SVTs. Group B comprised predominantly Fontan patients with more SVTs. Group C included more complex defects, such as intra-atrial baffle or interrupted inferior venous access, in which retrograde aortic and superior venous accesses were used exclusively with more frequent use of image integration (97.8%; P <0.001). Acute success was 91.5%, 83.7%, and 82.2%, respectively ( P =0.370). In group C, fluoroscopy time was the shortest (median, 4.2 min; P <0.001) despite the longer procedure duration (median, 253 min; P <0.001). SVTs free rates were 80.4%, 82.4%, and 75.8%, respectively ( P =0.787) during a mean 20-months follow-up period. Conclusions—: The combination of remote magnetic navigation, 3D-image integration, and electroanatomic mapping system facilitated safe and feasible ablation with very low fluoroscopy exposure even in patients with complex anomalies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.113.000415

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 105

Metadata

Authors
Ueda, A., Suman-Horduna, I., Mantziari, L., Gujic, M., Marchese, P., Ho, S. Y., Babu-Narayan, S. V., & Ernst, S.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2013-06
Volume
6
Issue
3
Pages
606-613
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2161048290
Cited by
105
References
1
FWCI
5.51
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.