The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Acute Hemodynamic Decompensation During Catheter Ablation of Scar-Related Ventricular Tachycardia: Incidence, Predictors, and Impact on Mortality
Open accessAbstract
Background—: The occurrence of periprocedural acute hemodynamic decompensation (AHD) in patients undergoing radiofrequency catheter ablation of scar-related ventricular tachycardia (VT) has not been previously investigated. Methods and Results—: We identified univariate predictors of periprocedural AHD in 193 consecutive patients undergoing radiofrequency catheter ablation of scar-related VT. AHD was defined as persistent hypotension despite vasopressors and requiring mechanical support or procedure discontinuation. AHD occurred in 22 (11%) patients. Compared with the rest of the population, patients with AHD were older (68.5±10.7 versus 61.6±15.0 years; P =0.037); had a higher prevalence of diabetes mellitus (36% versus 18%; P =0.045), ischemic cardiomyopathy (86% versus 52%; P =0.002), chronic obstructive pulmonary disease (41% versus 13%; P =0.001), and VT storm (77% versus 43%; P =0.002); had more severe heart failure (New York Heart Association class III/IV: 55% versus 15%, P <0.001; left ventricular ejection fraction: 26±10% versus 36±16%, P =0.003); and more often received periprocedural general anesthesia (59% versus 29%; P =0.004). At 21±7 months follow-up, the mortality rate was higher in the AHD group compared with the rest of the population (50% versus 11%, log-rank P <0.001). Conclusions—: AHD occurs in 11% of patients undergoing radiofrequency catheter ablation of scar-related VT and is associated with increased risk of mortality over follow-up. AHD may be predicted by clinical factors, including advanced age, ischemic cardiomyopathy, more severe heart failure status (New York Heart Association class III/IV, lower ejection fraction), associated comorbidities (diabetes mellitus and chronic obstructive pulmonary disease), presentation with VT storm, and use of general anesthesia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Logistic Regression in Rare Events Data
King, G., & Zeng, L. (2001) · Political Analysis · doi:10.1093/oxfordjournals.pan.a004868 · Cited by 4,316 · cited 1×
“Endo-epicardial approach, n (%) 44 (23) 2 (9) 42 (25) 0.”
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Self-citationDiabetic and Nondiabetic Patients With Left Main and/or 3-Vessel Coronary Artery Disease
Banning, A. P., Westaby, S., Morice, M.-C., Kappetein, A. P., Mohr, F. W., Berti, S., Glauber, M., Kellett, M. A., Kramer, R. S., Leadley, K., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.09.057 · Cited by 290 · cited 1×
“RV dysfunction (moderate/severe), n (%) 37 (19) 6 (27) 31 (18) 0.”
Cited by
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2019) · EP Europace · doi:10.1093/europace/euz132 · Cited by 475
Self-citation2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2019.03.002 · Cited by 431
Self-citationNielsen, J. C., Lin, Y.-J., de Oliveira Figueiredo, M. J., Sepehri Shamloo, A., Alfie, A., Boveda, S., Dagres, N., Di Toro, D., Eckhardt, L. L., Ellenbogen, K., et al. (2020) · EP Europace · doi:10.1093/europace/euaa065 · Cited by 98
Metadata
- Authors
- Santangeli, P., Muser, D., Zado, E. S., Magnani, S., Khetpal, S., Hutchinson, M. D., Supple, G., Frankel, D. S., Garcia, F. C., Bala, R., Riley, M. P., Lin, D., Rame, J. E., Schaller, R., Dixit, S., Marchlinski, F. E., & Callans, D. J.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2015-02
- Volume
- 8
- Issue
- 1
- Pages
- 68-75
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2323698394
- Cited by
- 207
- References
- 3
- FWCI
- 5.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Acute Hemodynamic Decompensation During Catheter Ablation of Scar-Related Ventricular Tachycardia: Incidence, Predictors, and Impact on Mortality. https://app.cochat.ai/papers/10.1161/circep.114.002155
- The paper
- Santangeli, P., Muser, D., Zado, E. S., Magnani, S., Khetpal, S., Hutchinson, M. D., Supple, G., Frankel, D. S., Garcia, F. C., Bala, R., Riley, M. P., Lin, D., Rame, J. E., Schaller, R., Dixit, S., Marchlinski, F. E., & Callans, D. J. (2015). Acute Hemodynamic Decompensation During Catheter Ablation of Scar-Related Ventricular Tachycardia: Incidence, Predictors, and Impact on Mortality. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.114.002155
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.