Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 224

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

High-Resolution Mapping of Scar-Related Atrial Arrhythmias Using Smaller Electrodes With Closer Interelectrode Spacing

Anter, Elad, Tschabrunn, Cory M., Josephson, Mark E. · 2015 · Circulation: Arrhythmia and Electrophysiology

Abstract

Background—: The resolution of mapping is influenced by electrode size and interelectrode spacing. Smaller electrodes with closer interelectrode spacing may improve mapping resolution, particularly in scar. The aims of this study were to establish normal electrogram criteria in the atria for both 3.5-mm electrode tip linear catheters (Thermocool) and 1-mm multielectrode-mapping catheters (Pentaray) and to compare their mapping resolution in scar-related atrial arrhythmias. Methods and Results—: Normal voltage amplitude cutoffs for both catheters were validated in 10 patients with structurally normal atria. In 20 additional patients with scar-related atrial arrhythmias, similar sequential mapping with both catheters was performed. Normal bipolar voltage amplitude was similar between 3.5- and 1-mm electrode catheters with a fifth percentile of 0.48 and 0.52 mV, respectively ( P =0.65). In patients with scar-related atrial arrhythmias, the total area of bipolar voltage <0.5 mV measured using 1-mm electrode catheters was smaller than that measured using 3.5-mm catheter (14.7 versus 20.4 cm2; P =0.02). The mean bipolar voltage amplitude in this area of low voltage was significantly higher with 1-mm electrode catheters (0.28 and 0.17 mV; P =0.01). Importantly, 54.4% of all low voltage data points recorded with 1-mm electrode catheter had distinct electrograms that allowed annotation of local activation time compared with only 21.4% with 3.5-mm electrode tip catheters ( P =0.01). Overdrive pacing with capture of the tachycardia from within the area of low voltage was more frequent with 1-mm electrode catheters (66.7 versus 33.4; P =0.01). Conclusions—: Mapping with small closely spaced electrode catheters can improve mapping resolution within areas of low voltage.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.114.002737

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 224

Metadata

Authors
Anter, E., Tschabrunn, C. M., & Josephson, M. E.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2015-06
Volume
8
Issue
3
Pages
537-545
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W1974424531
Cited by
224
References
1
FWCI
16.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Resolution Mapping of Scar-Related Atrial Arrhythmias Using Smaller Electrodes With Closer Interelectrode Spacing. https://app.cochat.ai/papers/10.1161/circep.114.002737
The paper
Anter, E., Tschabrunn, C. M., & Josephson, M. E. (2015). High-Resolution Mapping of Scar-Related Atrial Arrhythmias Using Smaller Electrodes With Closer Interelectrode Spacing. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.114.002737

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.