The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Impact of Substrate Modification by Catheter Ablation on Implantable Cardioverter–Defibrillator Interventions in Patients With Unstable Ventricular Arrhythmias and Coronary Artery Disease: Results From the Multicenter Randomized Controlled SMS (Substrate Modification Study)
Open accessAbstract
Background—: The implantable cardioverter–defibrillator (ICD) is the standard therapy to prevent sudden cardiac death in patients with coronary artery disease and unstable ventricular tachyarrhythmias. The prospective multinational SMS (Substrate Modification Study) was designed to assess whether prophylactic ablation of the arrhythmogenic substrate reduces or prevents the recurrence of ventricular tachycardia/ventricular fibrillation in such patients. Methods and Results—: Of 111 patients included in an intention-to-treat analysis, 54 were randomly assigned catheter ablation plus ICD implantation (ablation group: 68±8 years; 47 men), whereas 57 were assigned ICD implantation without catheter ablation (ICD-only group: 66±8 years; 46 men). Primary study end point was the time to first recurrence of ventricular tachycardia/ventricular fibrillation. ICD episodes were assessed and verified by an independent board. Patients were followed up for 2.3±1.1 years. The primary end point was reached by 25 ablation patients and 26 ICD-only patients. Two-year event-free survival was estimated at 49.0% (95% confidence interval, 33.3%–62.9%) in the former and 52.4% (36.7%–65.9%) in the latter groups. Comparison of episode incidence revealed no significant difference in the primary end point ( P =0.84). In an Andersen–Gill regression model with multiple end point recurrences, the difference between the study arms significantly favored catheter ablation for both the primary end point and all but one of the predefined subgroups of detected arrhythmia events. Conclusions—: SMS failed to meet the primary end point of time to first ventricular tachycardia/ventricular fibrillation recurrence. However, catheter ablation did reduce the total number of ICD interventions during the duration of follow-up. Clinical Trial Registration—: https://clinicaltrials.gov . Unique identifier: NCT00170287.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cox’s regression model for counting processes: A large sample study
Andersen, P. K., & Gill, R. D. (1982) · The Annals of Statistics · doi:10.1214/aos/1176345976 · Cited by 4,419
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
Prophylactic Catheter Ablation for the Prevention of Defibrillator Therapy
Reddy, V. Y., Reynolds, M. R., Neuzil, P., Richardson, A. W., Taborsky, M., Jongnarangsin, K., Kralovec, S., Sediva, L., Ruskin, J. N., & Josephson, M. E. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa065457 · Cited by 959
Cited by
Zeppenfeld, K., Tfelt-Hansen, J., de Riva, M., Winkel, B. G., Behr, E. R., Blom, N. A., Charron, P., Corrado, D., Dagres, N., de Chillou, C., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac262 · Cited by 3,140
Self-citation2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2019) · EP Europace · doi:10.1093/europace/euz132 · Cited by 475
Self-citation2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2019.03.002 · Cited by 431
Self-citationNielsen, J. C., Lin, Y.-J., de Oliveira Figueiredo, M. J., Sepehri Shamloo, A., Alfie, A., Boveda, S., Dagres, N., Di Toro, D., Eckhardt, L. L., Ellenbogen, K., et al. (2020) · EP Europace · doi:10.1093/europace/euaa065 · Cited by 98
Self-citation
Metadata
- Authors
- Kuck, K.-H., Tilz, R. R., Deneke, T., Hoffmann, B. A., Ventura, R., Hansen, P. S., Zarse, M., Hohnloser, S. H., Kautzner, J., & Willems, S.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2017-03
- Volume
- 10
- Issue
- 3
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2595915933
- Cited by
- 172
- References
- 4
- FWCI
- 11.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of Substrate Modification by Catheter Ablation on Implantable Cardioverter–Defibrillator Interventions in Patients With Unstable Ventricular Arrhythmias and Coronary Artery Disease: Results From the Multicenter Randomized Controlled SMS (Substrate Modification Study). https://app.cochat.ai/papers/10.1161/circep.116.004422
- The paper
- Kuck, K.-H., Tilz, R. R., Deneke, T., Hoffmann, B. A., Ventura, R., Hansen, P. S., Zarse, M., Hohnloser, S. H., Kautzner, J., & Willems, S. (2017). Impact of Substrate Modification by Catheter Ablation on Implantable Cardioverter–Defibrillator Interventions in Patients With Unstable Ventricular Arrhythmias and Coronary Artery Disease: Results From the Multicenter Randomized Controlled SMS (Substrate Modification Study). Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.116.004422
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.