CoChat

Central Cardiac Limit to Aerobic Capacity in Patients With Exertional Pulmonary Venous Hypertension: Implications for Heart Failure With Preserved Ejection Fraction

Open access
Santos, Mário, Opotowsky, Alexander R., Shah, Amil M., Tracy, Julie, Waxman, Aaron B., Systrom, David M. · 2015 · Circulation: Heart Failure
Cited by 62

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Background—: The mechanism of functional limitation in heart failure with preserved ejection fraction remains controversial. We examined the contributions of central cardiac and peripheral mechanisms and hypothesized that the pulmonary vascular response to exercise is an important determinant of aerobic capacity among patients with exertional pulmonary venous hypertension (ePVH). Methods and Results—: We compared 31 ePVH patients (peak V O 2 <80% of predicted and peak pulmonary arterial wedge pressure≥20 mm Hg) with 31 age- and sex-matched controls (peak V O 2 >80% predicted) who underwent invasive cardiopulmonary exercise testing for unexplained exertional intolerance. ePVH patients had lower peak cardiac output (73±14% versus 103±18% predicted; P <0.001) compared with controls, related both to impaired chronotropic response (peak heart rate 111±25 beats per minute versus 136±24 beats per minute; P <0.001) and to reduced peak stroke volume index (47±10 mL/min per m 2 versus 54±15 mL/min per m 2 ; P =0.03). Peak systemic O 2 extraction was not different between groups (arterial-mixed venous oxygen content difference: 13.0±2.1 mL/dL versus 13.4±2.4 mL/dL; P =0.46). ePVH patients had higher resting (150±74 versus 106±50 dyne/s per cm −5 ; P =0.009), peak (124±74 dyne/s per cm −5 versus 70±41 dyne/s per cm −5 ; P <0.001), and isoflow pulmonary vascular resistance (124±74 dyne/s per cm −5 versus 91±33 dyne/s per cm −5 at cardiac output≈10.6 L/min; P =0.04). Pulmonary vascular resistance decreased with exercise in all control subjects but increased in 36% (n=11) of ePVH patients. Abnormal pulmonary vascular response was not associated with peak V O 2 . Conclusions—: Reduced cardiac output response, rather than impaired peripheral O 2 extraction, constrains oxygen delivery and aerobic capacity in ePVH. Pulmonary vascular dysfunction is common in patients with ePVH at rest and during exercise.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circheartfailure.114.001551

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 62

Metadata

Authors
Santos, M., Opotowsky, A. R., Shah, A. M., Tracy, J., Waxman, A. B., & Systrom, D. M.
Venue
Circulation: Heart Failure
Published
2015-03
Volume
8
Issue
2
Pages
278-285
ISSN
  • 1941-3289 (ISSN-L)
  • 1941-3297
OpenAlex
W2136090099
Cited by
62
References
6
FWCI
22.21
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Central Cardiac Limit to Aerobic Capacity in Patients With Exertional Pulmonary Venous Hypertension: Implications for Heart Failure With Preserved Ejection Fraction. https://app.cochat.ai/papers/10.1161/circheartfailure.114.001551
The paper
Santos, M., Opotowsky, A. R., Shah, A. M., Tracy, J., Waxman, A. B., & Systrom, D. M. (2015). Central Cardiac Limit to Aerobic Capacity in Patients With Exertional Pulmonary Venous Hypertension: Implications for Heart Failure With Preserved Ejection Fraction. Circulation: Heart Failure. https://doi.org/10.1161/circheartfailure.114.001551

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.