CoChat

Accuracy and Usability of a Self-Administered 6-Minute Walk Test Smartphone Application

Open access
Brooks, Gabriel C., Vittinghoff, Eric, Iyer, Sivaraman, Tandon, Damini, Kuhar, Peter, Madsen, Kristine A., Marcus, Gregory M., Pletcher, Mark J., Olgin, Jeffrey E. · 2015 · Circulation: Heart Failure
Cited by 108

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Background—: The 6-minute walk test (6MWT) independently predicts congestive heart failure severity, death, and heart failure hospitalizations, but must be administered in clinic by qualified staff on a premeasured course. As part of the Health eHeart Study, we sought to develop and validate a self-administered 6MWT mobile application (SA-6MWTapp) for independent use at home by patients. Methods and Results—: We performed a validation study of an SA-6MWTapp in 103 participants. In phase 1 (n=52), we developed a distance-estimation algorithm for the SA-6MWTapp by comparing step counts from an Actigraph and measured distance on a premeasured 6MWT course with step counts and estimated distance obtained simultaneously from our SA-6MWTapp (best estimation algorithm, r=0.89 [95% confidence interval 0.78–0.99]). In phase 2, 32 participants (including those with congestive heart failure and pulmonary hypertension) used the SA-6MWTapp independently in clinic, and the distance estimated by the SA-6MWTapp was compared with the measured distance (r=0.83 [95% confidence interval 0.79–0.92]). In phase 3, 19 patients with congestive heart failure and pulmonary hypertension consecutively enrolled from clinic performed 3.2±1 SA-6MWTapp tests per week at home over 2 weeks. Distances estimated from the SA-6MWTapp during home 6MWTs were highly repeatable (coefficient of variation =4.6%) and correlated with in-clinic–measured distance (r=0.88 [95% confidence interval 0.87–0.89]). Usability surveys performed during the second (in-clinic) and third (at-home) phases demonstrated that the SA-6MWTapp was simple and easy to use independently. Conclusions—: An SA-6MWTapp is easy to use and yields accurate repeatable measurements in the clinic and at home.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circheartfailure.115.002062

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 108

Metadata

Authors
Brooks, G. C., Vittinghoff, E., Iyer, S., Tandon, D., Kuhar, P., Madsen, K. A., Marcus, G. M., Pletcher, M. J., & Olgin, J. E.
Venue
Circulation: Heart Failure
Published
2015-09
Volume
8
Issue
5
Pages
905-913
ISSN
  • 1941-3289 (ISSN-L)
  • 1941-3297
OpenAlex
W2156441323
Cited by
108
References
5
FWCI
11.10
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.