Background—: Elevated left ventricular filling pressure is a cardinal feature of heart failure with preserved ejection fraction. Mitral E/e′ ratio has been proposed as a noninvasive measure of left ventricular filling pressure. We studied the accuracy of E/e′ to estimate and track changes of left ventricular filling pressure in patients with unexplained dyspnea. Methods and Results—: We performed supine and upright transthoracic echocardiography in 118 patients with unexplained dyspnea who underwent right heart catheterization. Supine E/e′ ratio modestly but significantly correlated with supine pulmonary arterial wedge pressure (PAWP; r =0.36; P <0.001) and demonstrated poor agreement with PAWP values (Bland–Altman limits of agreement of −8.3 to 8.3 mm Hg; range, 6.5–21.2 mm Hg). Similarly, E/e′ ratio cut off of 13 performed poorly in identifying patients with elevated left ventricular filling pressure (sensitivity 6%, specificity 90%). The receiver-operating characteristic area of E/e′ was 0.65 (95% confidencce interval, 0.50–0.79). With change from the supine to upright position, PAWP decreased (−5±4 mm Hg; P <0.001) as did both E wave (−17±15 cm/s; P <0.001) and e′ (−2.7±2.7 cm/s; P <0.001) velocities, whereas E/e′ remained stable (+0.2±2.6; P =0.57). Positional change in PAWP correlated modestly with change in E-wave ( r =0.37; P <0.001) velocity. There was no appreciable relationship between change in PAWP and change in average E/e′ ( r =−0.04; P =0.77) and in half the patients the change in PAWP and E/e′ were directionally opposite. Conclusions—: In patients with unexplained dyspnea, E/e′ ratio neither accurately estimates PAWP nor identifies patients with elevated PAWP consistent with heart failure with preserved ejection fraction. Positional changes in E/e′ ratio do not reflect changes in PAWP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circheartfailure.115.002161

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 106

Metadata

Authors
Santos, M., Rivero, J., McCullough, S. D., West, E., Opotowsky, A. R., Waxman, A. B., Systrom, D. M., & Shah, A. M.
Venue
Circulation: Heart Failure
Published
2015-07
Volume
8
Issue
4
Pages
749-756
ISSN
  • 1941-3289 (ISSN-L)
  • 1941-3297
OpenAlex
W2212715350
Cited by
106
References
6
FWCI
8.92
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: E/e′ Ratio in Patients With Unexplained Dyspnea: Lack of Accuracy in Estimating Left Ventricular Filling Pressure. https://app.cochat.ai/papers/10.1161/circheartfailure.115.002161
The paper
Santos, M., Rivero, J., McCullough, S. D., West, E., Opotowsky, A. R., Waxman, A. B., Systrom, D. M., & Shah, A. M. (2015). E/e′ Ratio in Patients With Unexplained Dyspnea: Lack of Accuracy in Estimating Left Ventricular Filling Pressure. Circulation: Heart Failure. https://doi.org/10.1161/circheartfailure.115.002161

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.