The DOI matches its Crossref record.
Aortic Root Measurement by Cardiovascular Magnetic Resonance: Specification of Planes and Lines of Measurement and Corresponding Normal Values
Open accessAbstract
Background— Cardiovascular magnetic resonance is widely used for aortic root visualization and measurement, but methods still need to be standardized. Our aim was to identify appropriate planes of acquisition and lines of measurement and record corresponding normal values. Methods and Results— We studied 120 healthy volunteers, 10 of each gender in each decile between 20 and 80 years, by using a 1.5-T cardiovascular magnetic resonance system. Steady-state free precession cine acquisitions aligned with the left ventricular outflow tract in oblique sagittal and coronal orientations were used to locate 2 sinus planes that transected the root at its widest point in its maximally expanded systolic and at its end diastolic positions. We measured the cusp-cusp and the cusp-commissure dimensions in these cine planes, each as the average of 3. Diastolic cusp-commissure dimensions were smaller than diastolic cusp-cusp dimensions (32.0�3.5 mm versus 34.6�4.0 mm in men, 28.4�2.8 mm versus 30.7�3.3 mm in women, P <0.001 for both). The diastolic cusp-commissure dimensions increased by 0.9 mm per decade in men and 0.7 mm per decade in women ( P <0.001 for both) and gave higher R 2 values with respect to age and body surface area (0.40 for men, 0.27 for women) than diastolic cusp-cusp, systolic cusp-commissure, or sinus measurements made in the left ventricular outflow tract planes. Conclusions— The results indicate the importance of consistent methods for measurement of the aortic root by cardiovascular magnetic resonance. We recommend diastolic cusp-commissure measurements, which yielded favorable R 2 values with respect to age and body surface area and were found to correspond closely with reference echocardiographic root measurements recorded in the Framingham cohort. We recorded reference values for these and other possible aortic root measurements by cardiovascular magnetic resonance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Erbel (2014) · doi:10.1093/eurheartj/ehu281 · Cited by 4,451
2024 ESC Guidelines for the management of peripheral arterial and aortic diseases
Mazzolai, L., Teixido-Tura, G., Lanzi, S., Boc, V., Bossone, E., Brodmann, M., Bura-Rivière, A., De Backer, J., Deglise, S., Della Corte, A., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae179 · Cited by 993
Normal values for cardiovascular magnetic resonance in adults and children
Kawel-Boehm, N., Maceira, A., Valsangiacomo-Buechel, E. R., Vogel-Claussen, J., Turkbey, E. B., Williams, R., Plein, S., Tee, M., Eng, J., & Bluemke, D. A. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0111-7 · Cited by 746
Goldstein, S. A., Evangelista, A., Abbara, S., Arai, A., Asch, F. M., Badano, L. P., Bolen, M. A., Connolly, H. M., Cuéllar-Calàbria, H., Czerny, M., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.11.015 · Cited by 641
2014 ESC Guidelines on the diagnosis and treatment of aortic diseases
Erbel, R., Aboyans, V., Boileau, C., Bossone, E., Di Bartolomeo, R., Eggebrecht, H., Evangelista, A., Falk, V., Frank, H., Gaemperli, O., et al. (2014) · Kardiologia Polska · doi:10.5603/kp.2014.0225 · Cited by 458
Metadata
- Authors
- Burman, E. D., Keegan, J., & Kilner, P. J.
- Venue
- Circulation: Cardiovascular Imaging
- Published
- 2008-09
- Volume
- 1
- Issue
- 2
- Pages
- 104-113
- ISSN
- 1941-9651 (ISSN-L)
- 1942-0080
- OpenAlex
- W2547136736
- Cited by
- 186
- References
- 0
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Aortic Root Measurement by Cardiovascular Magnetic Resonance: Specification of Planes and Lines of Measurement and Corresponding Normal Values. https://app.cochat.ai/papers/10.1161/circimaging.108.768911
- The paper
- Burman, E. D., Keegan, J., & Kilner, P. J. (2008). Aortic Root Measurement by Cardiovascular Magnetic Resonance: Specification of Planes and Lines of Measurement and Corresponding Normal Values. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.108.768911
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.