Aortopulmonary Collaterals After Bidirectional Cavopulmonary Connection or Fontan Completion: Quantification With MRI
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background— Aortopulmonary collaterals (APCs) have been associated with increased morbidity after the Fontan operation. We aimed to quantify APC flow after bidirectional cavopulmonary connections and Fontan completions, using phase-contrast MRI, and to identify risk factors for the development of APCs. Methods and Results— APC blood flow was quantifiable in 24 of 36 retrospectively analyzed MRI studies. Sixteen studies were performed after the bidirectional cavopulmonary connections (group A) and 8 after the Fontan operation (group B). APC blood flow was calculated by subtracting the blood flow volume through the pulmonary arteries from that through the pulmonary veins. The ratio of pulmonary to systemic blood flow (Qp/Qs) was 0.93�0.26 in group A and 1.27�0.16 in group B. APC flow was 1.42 (0.58 to 3.83) L/min/m 2 and 0.82 (0.50 to 1.81) L/min/m 2 in groups A and B, respectively. The mean inaccuracies corresponded to 7.9�14.5% and 7.1�13.6% of ascending aortic flow in groups A and B, respectively. Qp/Qs was negatively correlated with a younger age at the time of the bidirectional cavopulmonary connections operation ( r =0.62, P =0.01) and positively correlated with the age at the time of the Fontan completion ( r =0.81, P =0.01). Patients with a previous right-sided modified Blalock-Taussig shunt had more collateral flow to the right lung than those without. Conclusions— APC blood flow can be noninvasively measured in bidirectional cavopulmonary connections and Fontan patients, using MRI in the majority of patients and results in a significant left-to-right shunt.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vascular endothelial growth factor induced by hypoxia may mediate hypoxia-initiated angiogenesis
Shweiki, D., Itin, A., Soffer, D., & Keshet, E. (1992) · Nature · doi:10.1038/359843a0 · Cited by 4,617
Cited by
Fratz, S., Chung, T., Greil, G. F., Samyn, M. M., Taylor, A. M., Valsangiacomo Buechel, E. R., Yoo, S.-J., & Powell, A. J. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-51 · Cited by 507
Self-citationKilner, P. J., Geva, T., Kaemmerer, H., Trindade, P. T., Schwitter, J., & Webb, G. D. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp586 · Cited by 429
SCMR Position Paper (2020) on clinical indications for cardiovascular magnetic resonance
Leiner, T., Bogaert, J., Friedrich, M. G., Mohiaddin, R., Muthurangu, V., Myerson, S., Powell, A. J., Raman, S. V., & Pennell, D. J. (2020) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-020-00682-4 · Cited by 328
Cardiovascular magnetic resonance phase contrast imaging
Nayak, K. S., Nielsen, J.-F., Bernstein, M. A., Markl, M., D. Gatehouse, P., M. Botnar, R., Saloner, D., Lorenz, C., Wen, H., S. Hu, B., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0172-7 · Cited by 264
Newburger, J. W., Sleeper, L. A., Frommelt, P. C., Pearson, G. D., Mahle, W. T., Chen, S., Dunbar-Masterson, C., Mital, S., Williams, I. A., Ghanayem, N. S., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.006191 · Cited by 206
Metadata
- Authors
- Grosse-Wortmann, L., Al-Otay, A., & Yoo, S.-J.
- Venue
- Circulation: Cardiovascular Imaging
- Published
- 2009-05
- Volume
- 2
- Issue
- 3
- Pages
- 219-225
- ISSN
- 1941-9651 (ISSN-L)
- 1942-0080
- OpenAlex
- W2547249403
- Cited by
- 192
- References
- 1
- FWCI
- 9.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.