Sex-Specific Pediatric Percentiles for Ventricular Size and Mass as Reference Values for Cardiac MRI: Assessment by Steady-State Free-Precession and Phase-Contrast MRI Flow

Sarikouch, Samir, Peters, Brigitte, Gutberlet, Matthias, Leismann;, Birte, Kelter-Kloepping, Andrea, Koerperich, Hermann, Kuehne, Titus, Beerbaum, Philipp · 2010 · Circulation: Cardiovascular Imaging

Abstract

Background— Cardiac MRI is important in the treatment of children with congenital heart disease, but sufficient normative data are lacking. For ventricular volumes and mass, we sought to deliver reference centiles and to investigate sex effects. Methods and Results— We included 114 healthy children and adolescents, uniformly distributed spanning an age range of 4 to 20 years, as required by the Lambda-Mu-Sigma method to achieve a percentile distribution, thus avoiding arbitrary age categories. Subjects underwent axial volumetry (1.5-T scanner) using standardized 2D steady-state free-precession and flow protocols. Percentiles were computed for age 8 to 20 years (99 subjects) because breath-holds were more consistent in this group. When indexed for body surface area or height, the centile curves of ventricular volumetric parameters showed allometric increase until adolescence, when a plateau was reached, with values comparable to published adult reference data. In contrast, ventricular mass centiles increased without plateau. There was a significant sex difference, with centiles reflecting larger values in boys than in girls ( P <0.05) when ventricular volumes were indexed to body surface area or height but not when indexed to weight (exception: mass). There was excellent agreement of axial and short-axis volumetry and of volumetric and flow-derived stroke volumes. Conclusions— Percentiles for ventricular volumes and mass in healthy children have been established to serve as reference values in pediatric heart disease. Significant sex differences were noted when indexing volumes to body surface area or height. Unisex centiles related to weight may be considered for chamber volumes albeit not for mass.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circimaging.109.859074

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 174

Metadata

Authors
Sarikouch, S., Peters, B., Gutberlet, M., Leismann;, B., Kelter-Kloepping, A., Koerperich, H., Kuehne, T., & Beerbaum, P.
Venue
Circulation: Cardiovascular Imaging
Published
2010-01
Volume
3
Issue
1
Pages
65-76
ISSN
  • 1941-9651 (ISSN-L)
  • 1942-0080
OpenAlex
W2076373681
Cited by
174
References
0
FWCI
8.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sex-Specific Pediatric Percentiles for Ventricular Size and Mass as Reference Values for Cardiac MRI: Assessment by Steady-State Free-Precession and Phase-Contrast MRI Flow. https://app.cochat.ai/papers/10.1161/circimaging.109.859074
The paper
Sarikouch, S., Peters, B., Gutberlet, M., Leismann;, B., Kelter-Kloepping, A., Koerperich, H., Kuehne, T., & Beerbaum, P. (2010). Sex-Specific Pediatric Percentiles for Ventricular Size and Mass as Reference Values for Cardiac MRI: Assessment by Steady-State Free-Precession and Phase-Contrast MRI Flow. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.109.859074

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.